Refrigerant Piping Connection; Vacuum Pumping - Toshiba RAS-10SA-E Service Manual

Split wall type
Hide thumbs Also See for RAS-10SA-E:
Table of Contents

Advertisement

8-5-1. Refrigerant Piping Connection

<Flaring>
(1) Cut the pipe with a pipe cutter.
90˚
Fig. 8-5-2
(2) Insert a flare nut into the pipe, and flare the pipe.
Die
Pipe
Fig. 8-5-3
<Tightening connection>
Align the centers of the connecting pipes and tighten
the flare nut as far as possible with your fingers. Then
tighten the nut with a spanner and torque wrench as
shown in the figure.
CAUTION
• Do not apply excess torque. Otherwise, the
nut may crack depending on the installation
conditions.
Outer diam.
Tightening torque
6.35 mm
15.7 (1.6 kgf·m)
9.52 mm
29.4 (3.0 kgf
Half union or packed valve
Externally
threaded
side
Use a wrench
to secure.
Fig. 8-5-4
Obliquity
Roughness
A (mm)
Outer
A
diam.
Imperial
6.35 mm
1.3 mm
9.52 mm
1.6 mm
(Unit : N·m)
Additional
tightening torque
19.6 (2.0 kgf·m)
·
m)
34.3 (3.5 kgf·m)
Flare nut
Internally
threaded
side
Use a torque wrench
to tighten.

8-5-2. Vacuum Pumping

AIR PURGE
Evacuate the air in the connecting pipes and in
the indoor unit using vacuum pump.
Do not use the refrigerant in the outdoor unit.
Warp
For details, see the manual of vacuum pump.
<Use of vacuum pump>
(1) Connect the charge hose (A) from the manifold
valve to the charge inlet of the gas side packed
valve.
(2) Connect the charge hose (B) to the port of vacuum
Rigid
pump.
0.7 mm
(3) Open fully the low pressure side handle of the
manifold valve.
1.0 mm
(4) Operate the vacuum pump.
(5) Close the low pressure side handle of manifold
valve after vacuumizing and stop the vacuum
pump.
Continue vacuumizing more than 15 minutes and
check the pressure gauge indicates –76 cmHg
(–1.013 10
(6) Open the stems of packed valves A and B all the
way.
(7) Securely tighten the stem cap to each of the
packed valve stems.
Indoor unit
– 29 –
5
Pa).
Manifold valve
Pressure gage
Low pressure side handle
Charge hose (A)
Outdoor unit
Gas
(ø9.52)
A
C
D
B
Liquid
(ø6.35)
Fig. 8-5-5
High pressure
side handle
Lo
Hi
Charge
hose (B)
Service port
VP
Packed
valve

Hide quick links: