Wiring works
How to connect your extended power cables
1 . Prepare the following tools .
Tools
Spec
Shape
2 . As shown in the figure, peel off the shields from the rubber and wire of the
power cable .
- Peel off 20 mm of cable shields from the pre-installed tube .
• For information about the power cable specifications for indoor and
outdoor units, refer to the installation manual .
CAUTION
• After peeling off cable wires from the pre-installed tube, insert a
contraction tube .
3 . Insert both sides of core wire of the power cable into the connection sleeve .
f Method 1
f
Push the core wire into the sleeve from both sides .
f Method 2
f
Twist the wire cores together and push it into the sleeve .
4 . Using a crimping tool, compress the two points and flip it over and compress another two points in the same location .
- The compression dimension should be 8 . 0 .
- After compressing it, pull both sides of the wire to make sure it is firmly pressed .
12
EHS MONO Kit-EU_IM_05388A-04_EN.indd 12
Crimping pliers
Connection sleeve (mm)
MH-14
20xØ6 . 5 (HxOD)
f Method 1
f
Compression
Compress it 4 times .
dimension
Insulation tape
Width 19mm
Power cable
Pre-installed tube for the power cable
f Method 2
f
5 mm
Contraction tube (mm)
70xØ8 . 0 (LxOD)
20
20
20
60
120
180
(Unit: mm)
20
Connection sleeve
Connection sleeve
Compress it 4 times .
5 mm
2016-06-23 오후 3:42:58