Adjusting The Gap Sensor Level Manually - SATO S84-ex Operator's Manual

Hide thumbs Also See for S84-ex:
Table of Contents

Advertisement

6.3.3

Adjusting the Gap Sensor Level Manually

The adjustment procedure for the Gap sensor level is as follows:
1
Continue the procedure from step 15 of
Section 6.3.2 Adjusting the I-mark
Sensor Level
Manually.
If you only want to adjust the Gap sensor level,
after selecting MANUAL in the SENSOR LEVEL
screen, press
ENTER button repeatedly until
SENSOR LEVEL GAP(E) screen is shown.
2
On the SENSOR LEVEL GAP(E) screen,
press the
buttons to set ADJUST
/
LEVEL to 2 and then press the
button.
The adjustment range of ADJUST LEVEL is from 0
to 3.
We recommend using the initial value, which is 2.
The light reception level adjustment of the Gap
sensor is shown.
First, adjust the "Low" reception level (voltage) of the Gap sensor.
3
Open the top cover and unlock the media
feed and media sensor assembly .
4
Physically place the liner  without the
label resting over the Gap sensor.
5
Press the media feed and media sensor
assembly  down to lock it.
To get the correct adjustment result, close the
media sensor assembly before performing the
adjustment.
6
Press the
buttons to change ADJUST
/
LEVEL until the GAP(R) value is 1.0 V or
lower.
The adjustment range of ADJUST LEVEL is from 0
to 127.
Note
The ADJUST LEVEL manipulates the potentiometer that
will be, therefore, reset to 90, the default value when
replacing the PCB or initializing the settings.
ENTER
1
2
6 Adjusting the Product
Gap sensors
area
Low level: ≤ +1.0V
S84-ex/S86-ex Operator Manual
275