Sagem MyX-4 Technical Documentation Manual page 69

Hide thumbs Also See for MyX-4:
Table of Contents

Advertisement

REMOVING / REPLACING THE VIBRATING
Proc Sheet 1 08
DEVICE
MyX-4
1/2
Tools :
- A 0.6mm torx screwdriver
- Tweezers
Preliminary operation :
1. Remove the back cover (
Proc sheet 0
01).
2. Remove the battery (
Proc sheet 0
02).
3. Remove the front cover (
Proc sheet 0
03).
4. Unscrew the six attachment screws on the electronic board.
5. Remove the assembly flange , then the display
(Proc sheet 1 01 / 1 02)
6. Remove the electronic
board.(Proc sheet 1
03)
Removal procedure :
1. With tweezers, remove the vibrating device (1) .
Placement procedure :
1. Place the vibrating device (1) into position on the plate (2), respecting the foolproof device.
Further operations :
1. Remove the electronic board on the assembly plate.
.(Proc sheet 1
03)
2. Replace the display
(Proc sheet
1.02)
3. Replace the assembly flange
(Proc sheet 1 01)
4. Position and tighten the six attachments screws with torx settings of 0,25 N.m.
5. Replace the front cover /battery / back cover
(Proc sheet 0 01 / 0 02 / 0
03).
6. Carry out the radio test
(Test Sheet
06).
Ref. SCT U33 SM DTS 004– Index A - 29/03/01
Page 5-32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Myx5-2Myv-55

Table of Contents