REMOVING / REPLACING THE KEYPAD LIGHT
Proc Sheet 1 03
GUIDE
myX-4
1/2
Tools :
- A 0.6mm torx screwdriver
Preliminary operation
2. Remove the back cover (
Proc sheet 0
01).
3. Remove the battery (
Proc sheet 0
02).
4. Remove the front cover (
Proc sheet 0
03).
Removal procedure :
1. Unscrew the six attachment screws on the assembly plate (1)
2. Remove the assembly flange
(Proc sheet
1.01)
3. Remove the assembly display
(Proc sheet
1.02)
4. Remove the light guide keypad (2).
Placement procedure :
1. Replace the new light guide keypad on its housing.
2. Replace the assembly display
(Proc sheet
1.02)
3. Replace the assembly flange
(Proc sheet
1.01)
4. Position and tighten the six attachments screws with torx couple of 0,25 N.m.
Further operations :
1. Replace the front cover
(Proc sheet 0
03).
2. Replace the battery
(Proc sheet 0
02).
3. Replace the back cover
(Proc sheet 0
01).
4. Carry out radio test
(Test Sheet
06).
Ref. SCT U33 SM DTS 004– Index A - 29/03/01