Siemens SIMATIC NET RUGGEDCOM RSG2488F Installation Manual page 54

Industrial
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG2488F:
Table of Contents

Advertisement

a
Siemens-specified severity levels
EMC Immunity Type Tests per IEEE 1613
Note
The RUGGEDCOM RSG2488F meets Class 2 requirements for an all-fiber configura-
tion and Class 1 requirements for copper ports. Class 1 allows for temporary commu-
nication loss, while Class 2 requires error-free and interrupted communications.
HV Impulse
Fast Transient
Oscillatory
Radiated RFI
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-14
IEC 60068-2-30
IEC 60068-2-31
RUGGEDCOM RSG2488F
Installation Manual, 11/2019, C79000-G8976-1351-05
Test
Description
Signal Ports
DC Power Ports
AC Power Ports
Dielectric
Signal Ports
Strength
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Enclosure ports
ESD
Enclosure Contact
Enclosure Air
Test
Cold Temperature
Change of Temperature
Humidity (Damp Heat, Cyclic)
Description
AC Power Ports
Description
Dry Heat
Free Fall
6.2 EMC and Environmental Type Tests
Test Levels
Test Levels
5 kV (Failsafe Relay Output)
5 kV
2 kV
1.5 kVDC
2 kV
± 4 kV @ 2.5 and 5 kHz
± 4 kV @ 5 kHz
2.5 kV Common Mode @ 1MHz
2.5 kV Common Mode
1 kV Differential Mode @ 1 MHz
35 V/m
± 2 kV
± 4 kV
± 8 kV
± 4 kV
± 8 kV
± 15 kV
Test Levels
Test Ad
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Nb
5 Cycles, -40 to 85°
C (40 to 185° F)
Test Db
95% (non-condensing)
55 °C (131 °F), 6 Cycles
Procedure 1, 2 falls from a
height of 250 mm (9.8 in)
Certification
Severity Levels
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic net ruggedcom rsg2488

Table of Contents