Modules
4.3 Installing/Removing Power Modules
1
2
Figure 4.4
Contamination hazard – risk of equipment damage
Prevent the ingress of water, dirts and other debris that may lead to premature
equipment failure. Always make sure slots are not left empty.
Note
Power modules are hot swappable. When installing/removing a power module, it is
not necessary to turn off power to the device.
Removing a Power Module
To remove a power module, do the following:
1.
2.
3.
34
1
Power Supply Module (PS1)
Power Supply Module (PS2)
Power Supply Modules
CAUTION
Loosen the screws that secure the module to the chassis until the module can be
removed.
2
1
Screws
1
Power Supply
2
Chassis
3
Figure 4.5
Removing a Power Supply
Slide the module out of the chassis.
Install a new or blank module to prevent the ingress of dust and dirt.