Operating Elements; Initial Operation; Operational Information - Tronic KH 3905 Operating Instructions Manual

Table of Contents

Advertisement

Operating Elements

A
Power inverter:
q
Fan (on the rear panel)
w
Operation LED/Overload indicator
e
On/Off switch
r
AC outlet
t
12 V connections (Red+/Black-)
B
Cable with connection terminals
C
Cable with 12 V vehicle plug
40 A automotive flat fuse
D

Initial operation

Unpacking
1. Remove the device from the packaging.
2. Remove all foils.
Warning:
Do not permit small children to play with plastic
packaging. There is a risk of suffocation!
Check the items supplied
Before putting the device into use check to ensure
that all of the items listed are present and that there
are no visible signs of damage.
-
Power inverter
-
1 Cable with connection terminals red/black
-
1 Cable with 12 V vehicle plug
-
1 40 A automotive flat fuse
-
This operating manual

Operational information

For continuous operation of devices via the power
inverter the vehicle socket must supply a voltage
between 11 - 15,5 V
the vehicle socket can be perhaps an automotive
battery or a regulated DC voltage like a transformer-
accumulator station. Before connecting the power
inverter check to see that the voltage source is supplying
sufficient power for operation. The required power
needed for operation can be calculated as follows:
Example
The voltage source should provide for a continuous
load of 300 W and also for a minimum of 30,5 A.
Note:
12 V vehicle power sockets supply max. 15 A,
therefore the voltage transformer must be con-
nected directly to the terminals of a car battery
with the clamps. Only in this way can 300 W
continuous power be achieved.
Attention!
Never connect the power inverter to a 24 V
supply system. Otherwise the device will be
damaged. The device can only be connected to
a voltage source with a rated voltage of 12 V.
- 4 -
. The voltage source of