Do-It-Yourself Maintenance

Oven Light Bulb Replacement

CAUTION
Before replacing the light bulb, be certain the
Oven Light Switch is in the off position. Let bulb
and cover cool completely before touching. If the
light bulb glass comes loose from the base, turn
the power to the oven OFF at the circuit breaker
panel, before attempting to remove the bulb
base from the socket.
Replace only with a recommended light bulb designed for
appliance oven use. DO NOT USE a standard household
light bulb in any oven.
To Replace the Light Bulb:
1. Make sure that oven light switch is in the OFF position .
2. Remove the light cover -
With a flat-blade screwdriver in one hand, use the
screwdriver as a small wedge to gently pry apart the
glass cover from the metal housing and hold the glass
in the other hand as it releases from the housing.
3. Remove the burned-out bulb. Replace it with a
recommended appliance light bulb only. Do not touch
bulb with fingers. Follow the bulb manufacturer's
instructions.
4. Replace the glass cover by aligning it with the housing
and pressing on both ends of the glass, with equal
force, until the cover snaps into position. Avoid
applying excessive force on the glass.
SYMPTOM
Intermittent sparking
More than four clicks of
igniter before lighting
Constant Sparking
CAUSE
Ceramic igniter is wet or dirty.
Burner ports are clogged.
Improper fit of burner cap onto
burner base.
Range is not properly grounded.
Electrical power supply is
polarized.

Power Failure

In the event of a power failure, only the standard
burners can be lighted manually. It is necessary to light
each standard burner individually.
If the range's cooktop is being used when the power
failure occurs turn all of the burner control knobs to the
OFF position. The standard burners can be lighted by
holding a match at the ports and turning the control
knob to the
position. Wait until the flame is burning
all the way around the burner cap before adjusting the
flame to the desired height. The two ExtraLow
burners on the left side cannot be used during a power
failure. Be sure to turn them OFF if a power failure
occurs because they will not turn back on until the
control knobs are turned OFF and then turned back on
again. See "What to do if you Smell Gas", inside front
cover.
If you have low gas pressure, contact your gas
company.
Intermittent or Constant Igniter Sparking
Intermittent or constant sparking of the sealed gas surface
burners can result from a number of preventable
conditions. Eliminate these conditions as indicated in the
chart.
Carefully dry or clean igniter.
Clean ports on burner cap with a wire, a
needle or straightened paper clip.
Align burner cap properly on burner base.
Refer to Installation Instructions. Have a
qualified electrician ground the range
properly.
incorrectly
Refer to Installation Instructions.
Have a qualified electrician ground the
range properly.
®