Mitsubishi Heavy Industries Manuals
Air Conditioner
FDTC60ZSXVF
Mitsubishi Heavy Industries FDTC60ZSXVF Manuals
Manuals and User Guides for Mitsubishi Heavy Industries FDTC60ZSXVF. We have
1
Mitsubishi Heavy Industries FDTC60ZSXVF manual available for free PDF download: Technical Manual
Mitsubishi Heavy Industries FDTC60ZSXVF Technical Manual (218 pages)
HYPER INVERTER PACKAGED Split system, air to air heat pump type
Brand:
Mitsubishi Heavy Industries
| Category:
Air Conditioner
| Size: 50.77 MB
Table of Contents
Table of Contents
2
1 Specifications
6
Ceiling Cassette-4Way Compact Type (FDTC)
6
Ceiling Suspended Type (FDE)
9
Duct Connected-Low/Middle Static Pressure Type (FDUM)
12
2 Exterior Dimensions
15
Indoor Units
15
Outdoor Units
20
Remote Control (Option Parts)
21
3 Electrical Wiring
23
Indoor Units
23
Outdoor Units
27
4 Noise Level
28
5 Characteristics of Fan
31
6 Temperature and Velocity Distribution
32
7 Piping System
35
8 Range of Usage & Limitations
37
9 Selection Chart
39
Capacity Tables
39
Ceiling Cassette-4Way Compact Type (FDTC)
39
Ceiling Suspended Type(FDE)
41
Duct Connected-Low/Middle Static Pressure Type (FDUM)
43
Correction of Cooling and Heating Capacity in Relation to Air Flow Rate Control (Fan Speed)
45
Correction of Cooling and Heating Capacity in Relation to One Way Length of Refrigerant Piping
45
Height Difference between the Indoor Unit and Outdoor Unit
45
10 Application Data
46
Installation of Indoor Unit
46
Ceiling Cassette-4Way Compact Type (FDTC)
46
Ceiling Suspended Type (FDE)
52
Duct Connected-Low/Middle Static Pressure Type (FDUM)
56
Effective Range of Cool/Hot Wind (Reference)
62
Electric Wiring Work Installation
63
Installation of Wired Remote Control (Option)
67
Installation of Outdoor Unit
80
11 Outline of Operation Control by Microcomputer
84
Remote Control
84
Operation Control Function by the Wired Remote Control
86
Operation Control Function by the Indoor Control
89
Auto Operation
89
Operations of Functional Items During Cooling/Heating
90
Dehumidifying (DRY) Operation
90
Timer Operation
91
Remote Control Display During the Operation Stop
92
Hot Start (Cold Draft Prevention at Heating)
92
Hot Keep
92
Auto Swing Control
93
Thermostat Operation
94
Filter Sign
95
Compressor Inching Prevention Control
95
Drain Pump Control
96
Drain Motor (DM) Control
96
Operation Check/Drain Pump Test Run Operation Mode
96
Cooling, Dehumidifying Frost Protection
97
Heating Overload Protection
97
Anomalous Fan Motor
98
Plural Unit Control - Control of 16 Units Group by One Remote Control
98
High Ceiling Control
98
Abnormal Temperature Thermistor (Return Air/Indoor Heat Exchanger) Wire/Short-Circuit Detection
99
External Input/Output Control (Cnt or Cnta)
99
Operation Permission/Prohibition
101
Temporary Stop Input
103
Selection of Cooling/Heating External Input Function
103
Fan Control at Heating Startup
104
Room Temperature Detection Temperature Compensation During Heating
104
Return Air Temperature Compensation
104
High Power Operation (RC-EX3 Only)
104
Energy-Saving Operation (RC-EX3 Only)
104
Warm-Up Control (RC-EX3 Only)
104
Home Leave Mode (RC-EX3 Only)
104
Auto Temp. Setting (RC-EX3 Only)
105
Fan Circulator Operation (RC-EX3 Only)
105
The Operation Judgment Is Executed Every 5 Minutes (RC-EX3 Only)
105
Auto Fan Speed Control (RC-EX3 Only)
105
IU Overload Alarm (RC-EX3 Only)
105
RC-EX3 Only)
105
Operation Control Function by the Outdoor Control
106
Defrosting Operation
106
Cooling Overload Protective Control
106
Cooling High Pressure Control
107
Cooling Low Outdoor Temperature Protective Control
107
Heating High Pressure Control
108
Heating Overload Protective Control
108
Heating Low Outdoor Temperature Protective Control
109
Compressor Overheat Protection
109
Current Safe
110
Current Cut
110
Outdoor Unit Failure
110
Serial Signal Transmission Error Protection
110
Rotor Lock
110
Outdoor Fan Motor Protection
110
Outdoor Fan Control at Low Outdoor Temperature
110
Refrigeration Cycle System Protection
111
12 Maintenance Data
112
Diagnosing of Microcomputer Circuit
112
Selfdiagnosis Function
112
Troubleshooting Procedure
115
Troubleshooting at the Indoor Unit
115
Troubleshooting at the Outdoor Unit
121
Check of Anomalous Operation Data with the Remote Control
122
Inverter Checker for Diagnosis of Inverter Output
124
Outdoor Unit Control Failure Diagnosis Circuit Diagram
125
Troubleshooting Flow
127
List of Troubles
127
Troubleshooting
128
5Kω at 25°C
166
(Short Circuit) 10 20 30
166
Applicable Model
169
Error Detection Method
169
Condition of Error Displayed
169
Presumable Cause
169
13 Technical Information
170
Ceiling Cassette-4Way Compact Type (FDTC)
170
Ceiling Suspended Type (FDE)
173
Duct Connected-Low/Middle Static Pressure Type (FDUM)
176
14 Option Parts
179
Wireless Kit
179
(A) FDTC Series (RCN-TC-24W-E2)
179
(B) FDE Series (RCN-E-E2)
187
(C) FDUM Series (RCN-KIT4-E2)
195
Simple Wired Remote Conrol (RCH-E3)
203
OA Spacer (FDTC Series)
209
Duct Joint (FDTC Series)
213
Filter Kit (FDUM Series)
214
Superlink E Board (SC-ADNA-E)
216
Advertisement
Advertisement
Related Products
Mitsubishi Heavy Industries FDTC60ZIXVD
Mitsubishi FDTC60VD
Mitsubishi Heavy Industries FDTC60VF
Mitsubishi Heavy Industries FDTC60ZJXVF
Mitsubishi Heavy Industries FDTC60VH
Mitsubishi Heavy Industries FDTC60ZSXW1VH
Mitsubishi Heavy Industries FDTC60ZSXVH
Mitsubishi Heavy Industries FDTC250VSDVD
Mitsubishi Heavy Industries FDTC28KXE6
Mitsubishi Heavy Industries FDTC100VSAWPVH
Mitsubishi Heavy Industries Categories
Air Conditioner
Remote Control
Heat Pump
Engine
Control Systems
More Mitsubishi Heavy Industries Manuals