Section 4
TROUBLESHOOTING
Table 4-2 Parameters
Type
Enable
Setup
Always
Setup
X200
Setup
X250
Setup
X500
Setup
X750
Setup
Always
Setup
Flooded
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Setup
Always
Cal
Always
Cal
Always
Cal
Always
Cal
Always
Cal
Always
Cal
Always
User
X200
User
X250
User
X500
User
X750
User
Always
User
Always
User
Always
User
Always
User
Always
User
Always
User
Always
User
Always
User
Always
Seq
Com Mod
Seq
Always
Seq
Always
Seq
Always
Seq
Always
Seq
Always
Seq
Always
18
Default
Min
Max
1
0
2
135
50
225
135
50
195
250
150
495
400
300
560
0
0
1
0
0
1
65
20
200
0
0
30
0
0
30
0
0
2
0
0
100000
0
0
100000
0
0
100000
0
0
100000
0
0
10000
0
-7
7
0
-7
7
0
-20
10
0
-7
7
0
-7
7
0
0
1
110
30
220
110
30
185
150
150
360
150
150
560
10
3
70
15
0
59
0
0
30
0
0
10
0
0
59
0
0
15
0
0
2
0
0
1
0
0
2
0
0
4
0
0
100000
1
1
16
1
1
16
70
20
185
10
2
59
0
0
250
Display Text
Comment
Press Trans
200,250,500, 750
P1 Max
250psi transducer
P1 Max
200psi transducer
P1 Max
500psi transducer
P1 Max
750psi transducer
Water Switch
Water pressure switch enable for water
cooled machines
Oil Switch
Oil switch enable for flooded screw
machines
Min Load Psi
Minimum acceptable Loaded P1 value
Stop Timer
If not 0, run unloaded for this time before
stopping
Lube Cycle
Prelube/Postlube timer
K8 Option
Disable, Lube Pump, Master Control
Load Hours
Hours machine has been loaded
Run Hours
Hours machine has been running
Load Cycles
Number of load cycles
Starts
Number of starts
Capacity
Used by monitor to determine system load
P1
P2
dP1
P3
P4
Fault on Warn
Force shutdown on warning
Unload
250psi transducer unload pressure
Unload
200psi transducer unload pressure
Unload
500psi transducer unload pressure
Unload
750psi transducer unload pressure
Load Delta
Differential pressure from unload pressure
Unload Time
Auto mode shut down after unloaded for
this time
Drain Interval
Time between drains (Minutes)
Drain Time
Duration of drain (Seconds)
Restart Time
Auto restart on power up if not 0 (Seconds)
Wye Delta
Wye to delta starter transition time
(Seconds)
Language
French, German, Italian, Spanish, English
Temp Units
Fahrenheit, Celsius
Press Units
Pressure units, Psi, Bar, kPa
Sequence by
Disabled,Com, Hours, Remote, Slave,
Time Of Day etc.
Seq Hrs
Used for Hours sequencing mode
Com Number
Communications ID number
Machines
Number of machines in a system
Low Press
Panic start next machine in sequence
Recover Time
Keeps multiple machines from starting at
same time (seconds)
Rotate
Used to force a machine to stop