ues reflect the machine configuration.
Model - Model number of machine.
Cooling - Air or Water.
Press Trans - Pressure transducer range 200, 250,
500.
P1 Max - Maximum discharge pressure.
KT Fluid - Yes or No, indicating fluid.
Water Switch - Water pressure switch, Yes or No.
Oil Switch - Oil pressure differential switch, Yes or
No.
Min Load Psi - Minimum acceptable load P1 pres-
sure setting. Separator Maintenance warning is dis-
abled for loaded P1 pressures below this value (i.e.,
during start-up).
Lube Cycle - Pre-lube/ Post-lube function timer - 0
seconds (disabled) to 30 seconds.
K8 Option - K8 output relay function selector -
Disabled, Oil pump prelube and postlube control,
Master Control for special external sequence con-
trol.
Stop Timer - Time to run machine before stopping.
Protect - Protect control parameters.
SUPERVISOR DESCRIPTION
Load Hours - Hours machine was running and
loaded.
Run Hours - Hours machine was running loaded
and unloaded.
Load Cycles - Number of load/unload cycles.
Starts - Number of machine starts.
Capacity - Maximum capacity of machine.
Spiral Valve - (VSD packages only) Yes or No, indi-
cating spiral valve control.
VSD- Describes signal from Supervisor controls to
the VSD controls:
None - No VSD
Pressure - The Supervisor pressure singal is
connected to a drive analog input
Serial - The drive is connected on the
Supervisor serial data bus
Speed - The Supervisor provides a speed sig-
nal to a drive analog input.
Com Module - Yes/No Enables or disables the
communication module if installed.
Mtr Module - Yes/No
motor actuator module if installed.
Section 2
Enables or disables the
9