Section 4
TROUBLESHOOTING
Table 4-1A Analog Alarms (Flooded Screw Compressors Less Than 200 psi)
Sensor
P_1
P_1
P_1
P_2
P_3
P_4
T_1
T_1
T_1
T_1
T_1
T_1
T_2
T_2
T_2
T_3
T_3
T_4
T_4
(*) In the 'Check' column above, alarms are checked:
Constantly - if machine running or stopped
When Running - if machine is running
If Enabled - if parameter is non-zero
At Start - will not allow start if alarm present
Over Min Psi - machine is loaded and above min load pressure
16
Type
Limit
High Inhibit
5
Low Fault
5
High Fault
500
High Fault
500
High Fault
500
High Fault
500
Low Fault
-40
High Warn
225
High Fault
235
High Warn
245
High Fault
255
High Fault
500
Low Fault
-40
High Warn
225
High Fault
235
Low Warn
-40
High Warn
500
Low Fault
-40
High Fault
500
Start
Run
Delay
Delay Check (*)
0
0
At Start
5
0
When Running
0
0
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
5
30
Constantly
5
30
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
5
30
Constantly
5
30
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
0
0
Constantly
Comment
High sump psi at start
Immediate Fault
Sensor failure fault
Sensor failure fault
Sensor failure fault
Sensor failure fault
Sensor failure fault
Delayed for temp spikes
Delayed for temp spikes
Immediate Warning
Immediate Fault
Sensor failure fault
Sensor failure fault
Delayed for temp spikes
Delayed for temp spikes
Sensor failure warning
Sensor failure warning
Sensor failure fault
Sensor failure fault