18.1 information and advanced setting mode
To access the Information and Advanced Setting mode, it is necessary to press, for at least 3 seconds, the Ip button; in
INFO mode the display shows "InFo".
To escape the INFO mode briefly press the Ip button. In this mode press the oK button to scroll the windows; to set
parameters press the +/-
central HeatInG (cH)
"cH sl"
Max. heating circuit setpoint, value settable with the buttons +/-
•
WarnInG: to change the unit of measure from °C to °F and vice versa, press the
"eXt°c"
•
Outside temperature (with external sensor connected).
•
"cH o>"
Maximum Heating flow temperature.
•
"cH r<"
Return heating temperature (unplanned).
•
"cH s^"
CH temperature setpoint.
•
"cH MX"
Maximum CH temperature setpoint (max. settable value).
•
"cH Mn"
Minimum CH temperature setpoint (min. settable value).
DoMestIc Hot Water (D.H.W.)
•
"HW o>"
D.H.W. flow temperature.
•
"HW s^ "
Maximum setpoint temperature value setting. Press the +/-
•
"HW MX"
Maximum D.H.W. temperature setpoint (max. settable value).
•
"HW Mn"
Minimum D.H.W. temperature setpoint (min. settable value).
aDVanceD InForMatIon
"pWr %"
•
Power level/modulating flame (%).
"p Bar"
•
Water pressure heating circuit (bar).
"F l/M"
•
Water flow rate (l/min).
paraMeters settInG
•
"K reG" Central Heating setting constant (0,5...6,5 - factory setting 3 - Refer to section 8 - Graph 3).
Press +/-
buttons to set the value. An high value setting involves a high flow temperature. To set a correct value
of the Central Heating constant K REG, involves the room temperature to match the CH setpoint with external tem-
perature changes over.
•
"BuIlD" A parameter that takes into account the degree of building insulation (1..10 - factory setting 5). When the
outside temperature varies, the room temperature changes at different rates, depending on the building thermal sto-
rage capacity. An high value setting involves a heavy building structures (the room temperature will respond slower
to outside temperature variations; buildings with thick walls or with external insulation). A low value setting involves
a light building structures (the room temperature will respond quicker to outside temperature variations; buildings
with a light envelope).
Press +/-
buttons to set the value.
•
"YselF" CH flow temperature auto setting function Enabled/Disabled (1/0). Factory setting 1. With function enable,
the constant "K reG" is modified to match the room temperature comfort. This function operates with the external
sensor connected.
Press +/-
buttons to set the value.
"aMBon" Room temperature influence Enabled/Disabled (1/0). Factory setting 1. In this case, the rooms tempera-
•
ture regulation it depends on the flow temperature set ("CH SL").
Press +/-
buttons to set the value.
note: refer to the summary table of possible aMBon and MoDul combinations.
InstructIons pertaInInG to tHe Installer
18. parameters display
button.
.
buttons to set the value.
35
button.