Domestic Hot Water Mode (Fig. )
1. Priority is given to the domestic hot water supply. A demand at a tap or shower will override any central heating requi-
rement.
. The flow of water will operate the DHW flow switch which requests the 3 way valve to change position. This will allow
the pump to circulate the primary water through the DHW plate heat exchanger.
3. The burner will light automatically and the temperature of the domestic hot water is controlled by the temperature
sensor.
4. When the domestic hot water demand ceases the burner will extinguish and the diverter valve will remain in the dome-
stic hot water mode, unless there is a demand for central heating.
Key
1
Primary Heat Exchanger
2
Burner
3
Ignition Electrode
4
Flame Sensing Electrode
5
Gas Valve
6
Pump
7
Automatic Air Vent
8
Expansion Vessel
9
Plate Heat Exchanger
10
Flow Sensor with Filter
11
Boiler Drain Point
12
Pressure Relief Valve
13
Heating Return
14
Cold Water Inlet On/Off Valve and Filter
15
Gas Inlet
16
Domestic Hot Water Outlet
17
Heating Flow
18
Automatic By-Pass
19
Water Pressure Switch
20
Manometer
21
Domestic Hot Water Temperature Sensor
22
Three Way Valve
23
Three Way Valve Motor
24
Safety Thermostat
25
Central Heating Temperature Sensor

Frost protection Mode

1. Boilers electronic management includes a "frost protection" function in the central heating system which operates the
burner to reach a heating flow temperature of 30°C when the system heating flow temperature drops below 5 °C. This
function is enabled when the boiler is connected to electrical supply, the gas supply is on and the system pressure is as
required.

pump protection

1. In the event that no heat is required, the pump will automatically start up and operate for one minute during the fol-
lowing 24 hours. This function is operative when the boiler is powered.