TANDBERG Gatekeeper/Border Controller API D14172.01 User Manual page 35

Tandberg gatekeeper/border controller api user guide
Table of Contents

Advertisement

2.6.2 xpreferences
The special command xpreferences lets the user/control application individually configure the
Telnet/RS-232 session in use.
xpreferences ?
usage: xpreferences xpathwrite <on/off>
or:
xpreferences detaillevel <1..2>
or:
xpreferences xmlconfigfeedback <on/off>
or:
xpreferences xmlstatusfeedback <on/off>
or:
xpreferences xmlcommandresult <on/off>
OK
xpreferences xpathwrite <on/off>
This command disables/enables the XPath engine when issuing configurations. When the XPath
engine is disabled, the user/control application must supply the complete path to the configurations to
be set (no "double slashes" allowed). This will improve the performance of the system when issuing
many consecutive configurations.
NOTE! It is always recommended to supply the complete path for configurations to be set when
issuing commands from an external control application.
xpreferences detaillevel <1..2>
This command has no effect on the Gatekeeper and Border Controller.
xpreferences xmlconfigfeedback <on/off>
If xmlconfigfeedback is set to on, feedback on configurations will be returned in XML-format instead of
the standard XACLI configuration format.
Example 2.25
XACLI-format:
*c SNMP SystemContact: Administrator
XML-format:
<Configuration>
<SNMP item="1">
<SystemContact item="1">Administrator</SystemContact>
</SNMP>
</Configuration>
D14172.01
TANDBERG Gatekeeper/Border Controller API User Guide
page 35 of 84

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gatekeeper/border controller

Table of Contents