1
Double-click an ID to set, or select the ID and click
the [Edit] button.
2
Enter a source number and destination number in
the dialog.
Source Port Number: Enter a source number to
associate with the monitor target destination.
Monitor Target Number: Enter the monitor target
destination number of the destination monitor.
3
Click the [Apply] button.

Salvo Table Page

(Not supported on the MKS-E1620.)
Use to configure a salvo for switching multiple crosspoints
at the same time.
A salvo can be a snapshot salvo in which switching
crosspoint settings are registered in a system controller, or
a local salvo where settings are registered in the remote
control panel.
Setting a snapshot salvo
1
Double-click an ID to set in [Salvo Table], or select
the ID and click the [Edit] button.
2
Set [Mode] to [Snapshot] in the dialog.
3
Enter [Snapshot ID] and [Assigned Source] settings.
4
Click the [Apply] button.
Setting a local salvo
1
Double-click an ID to set in [Salvo Table], or select
the ID and click the [Edit] button.
2
Set [Mode] to [Local] in the dialog.
3
Enter [Name] and [Assigned Source] settings.
4
Click the [Apply] button.
5
Click the [+] button in [Xpt Table].
6
Specify the destination in the dialog, and set the
source and level.
7
Click the [Apply] button.
Setting a destination offset local salvo
In a destination offset local salvo, a salvo is executed for a
destination determined by adding an offset value to the
control destination.
1
Click the [+] button in [Xpt Table].
2
Set [Mode] to [Offset] in the dialog, and enter an
offset value.
3
Select a level.
4
Click the [Apply] button.

Available Src/Dest Page

(Not supported on the MKS-E1620.)
Use to set the range of sources/destinations available for
selection on the unit.
Adding a selectable source/destination
1
Click the [+] button for [Available Source] or
[Available Destination].
2
Specify the range of sources or destinations to
enable in the dialog.
To specify a single source/destination, enter a value in
either [From] or [To].
3
Click the [Apply] button.
The specified source/destination is added to the list in
[Available Source] or [Available Destination].
The sources/destinations displayed in these lists are
available for selection from the unit.
4
Repeat steps 1 to 3 until finished the configuration.
5
Click the [Save] button.
Deleting a source/destination
1
Select a row to delete in [Available Source] or
[Available Destination].
2
Click the [–] button.
3
Repeat steps 1 and 2 until finished the
configuration.
4
Click the [Save] button.

Control Area Page

(Not supported on the MKS-E1620.)
Use to set the range of sources available for selection for
the specified destination.
Example settings
No.
Source range
1
0001 to 3000
2
5001 to 8000
3
5001 to 8000
The selectable range for the above settings is shown
below.
16
Destination range
0001 to 3000
0001 to 3000
5001 to 8000

Advertisement