Drop Through Anchor - Honeywell Miller RACDTA-5K6/6FT User Instruction Manual

Swivel anchors
Table of Contents

Advertisement

4.0 Drop Through Anchor

5,000 lbf./22kN
Model Numbers RACDTA-5K/6FT (Drop though anchor with 4 in. (10 cm) round plate and
swivel), RACDTA-5K6/6FT (Drop through anchor with 6 in. (15 cm) square plate and swivel),
and RACDTA-5K12/6FT (Drop through anchor with 12 in. (30cm) square plate and swivel).
Warnings and Limitations
Use only with Honeywell-approved personal fall arrest or restraint systems. The anchorage
must have the strength capable of supporting a static load, applied in the directions
permitted by the system, of at least 5,000-lbf (22kN) in the absence of certification.
Tensile Strength (UTS): 5,000-lbf (22kN)
Working Load (WLL): 1,000 lbs (454kg)
Maximum Capacity: One worker, 310 lbs (140 kg)
Weight: Varies by cable length
Regulatory Compliance
ANSI Z359.1-2007, ANSI Z359.7-2011, OSHA 1910.66 , 1926.502
Installation:
1. The drop through anchor-5k drop through anchor can only be used on a horizontal
surface that is above the users location.
2. Locate or create a through hole in concrete, steel or metal grating capable of
withstanding a 5,000-lbf. Static load or meeting OSHA 1926.502 requirements for a
safety factor of two. (Reference figure 1-A below for dimentional requirements.)
3. Place cable through the hole from top side. The label on plate should be facing up.
Plate must rest flat and flush on the mounting surface.
Fig. 1-A
Material:
Concrete
Steel
Us er Ins tru ct ion s - Engl is h
1-3/4" to 2"Ø
Hole size
(4.1cm to 4.4cm)
HOLE REQUIRMENT CHART
(A)" Minimum distance from edge/corner
12" in. (30.5 cm)
4" in. (10 cm)
6
(B)
min
(B)" thickness
4" in. (10 cm)
1/4" in. (.635 cm)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents