CONCRETE MOUNTING
- Use a proper drill & bit for concrete. (SDS drill bit)
- Drill a 3/4" (19mm) hole no less than 5" (127mm) deep 9" (229mm) away from any edge.
- Hole must be straight & perpendicular to surface.
- Hole must be free of debris
- Concrete strength must be at least 3000psi (20.7MPa) and no less than 7" (178mm) thick.
WELD ON MOUNTING
Grade - 5 or 8 bolt
5/8"-11 x 1-3/4"
15/16" socket required
* Welding procedure must be approved by an Engineer or other qualified
person to be compatible with any and all structural & operational charac-
teristics of the selected installation location.
Us er Ins tru ct ion s - Engl is h
3/4" (19mm)
drill
Ø
Torque:
125-ft-lbs
(169Nm)
3/8"min.
(9.5mm)
Torque:
90ft-lbs
(120Nm)
16
7"
(178mm)
min.
4" min (102mm)
Embedment Depth
Puck
* Weld