System Configuration
Quick Setup,
continued
Calibrate Room Setup Screen
Auto Calibration Screen
LEFT
0
DB
L SURR
0
FT
L BACK
0
FT
Any speaker not configured in
the SPEAKER SETUP menu
displays N/A (not available) for the
dB specification.
External program material,
such as a test disc is required
for this calibration procedure.
P/N 309798
© 2007 by Krell Industries, Inc. All rights reserved. Krell
v 07.2
"DTS", "DTS Digital Surround", "DTS ES Extende
marks of Dolby Laboratories. Confidential Unpublished Works. Copyright 1992–1997 Dolby Laboratories, Inc. All rights reserved. HDMI, the HDMI logo and High-Definition Multimedia Interface are
trademarks or registered trademarks of HDMI Licensing LLC. THX is a registered trademark of Lucasfilm, Ltd. All other trademarks and trade names are registered to their respective companies.
STEP 6
Select
SPEAKER LEVEL
appears.
S–1000
-CALIBRATE ROOM SETUP-
SELECT THE CALIBRATION
METHOD
AUTO NOISE SEQUENCE
MANUAL NOISE SEQUENCE
PROGRAM MATERIAL
Select AUTO NOISE SEQUENCE
CALIBRATION
S–1000
-AUTO CALIBRATION-
CENTER
RIGHT
0
0
DB
DB
SUB
R SURR
0
0
DB
DB
C BACK
R BACK
0
N/A
FT
Repeat this process for the remaining loudspeakers. When all the loudspeakers are
calibrated, press the previous key twice to return to the main menu screen.
MANUAL NOISE SEQUENCE
This option allows you to manually move from loudspeaker to loudspeaker during
the calibration process. When the
SLP instructions under auto calibration, above. Noise will not migrate automatically.
Press enter to set each selection and move to the next loudspeaker using the direc-
tional keys on the remote. Repeat this process until all loudspeakers are calibrated.
PROGRAM MATERIAL
This option allows you to adjust loudspeaker levels based on your listening prefer-
ences rather than on SPL meter readings. The program material option uses the
same screen as the automatic or manual noise sequence. The source plays, simul-
taneously, from all configured loudspeakers. Use the enter and direction keys to
individually adjust loudspeaker levels. If any channels are not present in the source
material, they will not be heard during this process.
MODEL
®
is a registered trademark of Krell Industries, Inc., and is restricted for use by Krell Industries, Inc., its subsidiaries, and authorized agents.
d
Surround", and "Neo:6" are registered trademarks of Digital Theater Systems, Inc. "Dolby," "Pro Logic," and the double-D symbol are trade-
from the main menu. The
This screen enables you to select the calibration
method you want to use for your loudspeakers.
A sound pressure level (SPL)
meter is required for the auto
or manual noise sequence
calibration procedure.
from the calibrate room setup menu. The
screen appears.
This screen enables you to calibrate each channel
using the internal noise generator of the S–1000.
Set the SPL meter to
After initializing, the
screen blinks, and you hear band limited white noise
through the left loudspeaker. This noise continues for
two seconds and then moves clockwise to the next
loudspeaker in the system.
While the individual channel on screen is blinking, use
the direction keys to adjust each loudspeaker's setting
until the SPL meter reads
made while the channel on screen is blinking.
AUTO CALIBRATION
CALIBRATE ROOM SETUP
weighting and slow response.
C
channel dB setting on the
LEFT
. Adjustments must be
75 dB
screen appears, follow the
SERIAL NUMBER
screen
AUTO

Advertisement

loading