How The Drain Pump Operates; Operation - EdgeStar IB450SSP Owner's Manual

Built-in ice maker with internal pump
Hide thumbs Also See for IB450SSP:
Table of Contents

Advertisement

How the drain pump operates

The components of the drain pump are the:
• Water reservoir
• Circuit Board
• Water level switches 1 & 2
• Water Drain Pump

Operation

• All water coming from the overflow, and from the melted ice is collected inside the water
reservoir.
• As soon as the water in the reservoir reaches the maximum level, the water level switch 1 will
close, transmitting a low voltage current to the circuit board. The circuit board activates the
water drain pump for 20 seconds, pumping out most of the water contained in the reservoir.
• If the water lever switch 2 closes, it will transmit a low voltage current to the circuit board. The
circuit board activates the buzzer alarm, informing the user that the drain pump, water level
switch or drain tube is malfunctioning. If this happens, power the unit off and back on. If the
problem persists, contact customer service.
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents