Detecting Leaks In Refrigerant Circuit Using Leak Detecting System Vas 6196 Or Leak Detecting; System Vas 6201 Or A Later Model - Volkswagen Amarok 2011 Workshop Manual

Hide thumbs Also See for Amarok 2011:
Table of Contents

Advertisement

Amarok 2011 ➤ , Beetle 2012 ➤ , Bora 1999 ➤ , CC 2010 ➤ , CC 2012 ➤ , ...
6.3
Detecting leaks in refrigerant circuit us‐
ing leak detecting system - VAS 6196-
or leak detecting system - VAS 6201- or
a later model
Note
Small leaks can be detected with, for example, an UV leak de‐
tector additive.
– Evacuate refrigerant circuit using an air conditioner service
station
⇒ page 50
.
Note
If a larger leak is detected during the evacuation process, de‐
termine cause and rectify as described
If during the evacuation process no leak is detected or a very
small leak is detected that but cannot be located, proceed as
follows
⇒ page 56
.
Refrigerant gas is quickly dispersed by air motion. Therefore
drafts must be avoided during a search for leaks.
If the refrigerant circuit is completely empty, charge with about
10% of refrigerant capacity (sticker R134a or vehicle-specific
workshop manual).
Leak detecting system - VAS 6196-
or
Leak detecting system - VAS 6201- or later model
1 -
Hand pump with low-pressure service hose, service cou‐
pling and non-return valve - VAS 6201/1-
2 -
Cartridge - VAS 6201/2-
3 -
Cleaning solution - VAS 6201/3-
4 -
UV leakage detector lamp - VAS 6201/4-
5 -
UV absorbing eye protection - VAS 6201/6-
6 -
Label - VAS 6201/7-
7 -
Tube
VAS 6201/8
8 -
Protective gloves - VAS 6201/9-
Air conditioning system with refrigerant R134a - Edition 10.2014
⇒ page 50
.
6. Detecting leaks in refrigerant circuit
59

Hide quick links:

Advertisement

Table of Contents
loading