2.1.14
High-pressure safety valve
The high-pressure safety valve is fitted to the air conditioner com‐
pressor or the receiver.
The valve opens at a pressure above approx. 38 bar and closes
again when the pressure has dropped (approx. 30 bar).
Not all the refrigerant is lost from the system.
Depending on the version, a transparent plastic disc may be fitted,
which breaks when the valve opens.
2.2

Design of refrigerant circuit

2.2.1
Refrigerant circuit with expansion valve
and evaporator
1 -
Evaporator
2 -
Expansion valve
3 -
Valve for extracting, charging and measuring
4 -
Receiver with dryer bag or dryer cartridge
5 -
Condenser
6 -
Air conditioner compressor
Note
Arrows show the direction of refrigerant flow.
2.2.2
Refrigerant circuit with restrictor and
reservoir
1 -
Air conditioner compressor
2 -
Condenser
3 -
Restrictor
4 -
Evaporator
5 -
Reservoir with dryer cartridge
Note
Arrows show the direction of refrigerant flow.
2.3
Evacuation and charging valves for
quick-release couplings of air condition‐
er service station on refrigerant circuit
Special tools and workshop equipment required
♦ Torque wrench - V.A.G 1783- (2...10 Nm) with 1/4" ratchet
adapter - VAS 6234-
Air conditioning system with refrigerant R134a - Edition 10.2014
2. General information on refrigerant circuit
25