Air conditioning system with refrigerant R134a - Edition 10.2014
The reservoir or receiver is damaged (e.g. in an accident).
Caution
♦ Handling refrigerant ⇒ Volkswagen ServiceNet; Service
handbook; Environmental protection; Waste disposal;
Current situation; Disposal channels; Disposal of used
oils; Refrigerant oils .
11.1
In the event of leaking or damaged com‐
ponents (apart from the air conditioner
compressor, receiver or reservoir)
11.1.1
If the refrigerant circuit was completely
empty
– Remove defective part.
– Remove air conditioner compressor.
– Remove oil drain screw from air conditioner compressor.
Note
To speed up the draining of the refrigerant oil, rotate the shaft
of the air conditioner compressor by hand using the poly V-
belt pulley or the magnetic clutch.
Pour old refrigerant oil out of air conditioner compressor, han‐
dling refrigerant oil ⇒ Volkswagen ServiceNet; Service hand‐
book; Environmental protection; Waste disposal; Current
situation; Disposal channels; Disposal of used oils; Refrigerant
oils .
Then fill the air conditioner compressor with the quantity of
new refrigerant oil corresponding to the quantity in a genuine
air conditioner compressor ⇒ Rep. gr. 87 .
Different types and quantities of refrigerant oils are required
for different air conditioner compressors ⇒ Rep. gr. 87 .
To ensure proper lubrication of the air conditioner compressor
when it runs for the first time, the air conditioner compressor
must be filled with at least 80 cm
mainder can be poured into the new reservoir or receiver ⇒
Rep. gr. 87 .
If dirt enters the air conditioner compressor whilst the refrig‐
erant circuit is open (e.g. after an accident), the air conditioner
compressor should be renewed.
Blow through refrigerant circuit with compressed air and re‐
move moisture with nitrogen
– Renew receiver or reservoir and restrictor.
– Assemble the refrigerant circuit, evacuate it and charge it.
11.1.2
If there is still refrigerant in the refriger‐
ant circuit
– Drain refrigerant circuit.
160
Rep. gr.00 - Technical data
3
of refrigerant oil; the re‐
⇒ page 65
.