Table Of Contents; Introduction; General Information - Superior SSBV-3530CNE Homeowner's Care And Operation Instructions Manual

Ssbv-35/40 series b-vent gas fireplaces, millivolt and electronic models
Hide thumbs Also See for SSBV-3530CNE:
Table of Contents

Advertisement

CONGRATULATIONS!
In selecting this SUPERIOR B-Vent Gas Appliance you have chosen the finest and most
dependable fireplace to be found anywhere. Its a beautiful, prestigious alternative to a
wood burning fireplace. Welcome to a Family of tens of thousands of satisfied SUPERIOR
Fireplace Owners.
Please carefully read and follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your SUPERIOR product.

TABLE OF CONTENTS

Introduction .......................................Page 3
General Information ...........................Page 3
Burn-In Period ...................................Page 4
Variable Flame Adjustment . ................Page 5
Maintenance . ......................................Page 5
Logs, Volcanic Stone & Ember
Placement ......................................Page 8
Burner Adjustments ...........................Page 11
Millivolt Appliance Checkout ..............Page 11
Wiring Diagrams ................................Page 12
Warranty ............................................Page 13
Accessory Components .....................Page 13
Maintenance Schedule .......................Page 20
Replacement Parts List ......................Page 23

INTRODUCTION

The millivolt appliances have a millivolt gas
control valve with a piezo ignition system which
provides safe, efficient operation.
The electronic appliances have an electronic
intermittent pilot system provides safe, efficient
operation. External electrical power is required
to operate these units.
LISTING AS FOLLOWS:
These appliances comply with National Safety
Standards and are tested and listed by Omni-
Test Laboratories (Report No. 116-F-30-5)
to ANSI Z21.50 - 2003 (in Canada, CSA 2.22
- 2003), and CAN/CGA-2.17-M91 in both USA
and Canada, as vented gas fireplaces.
Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas Code,
ANSI Z223.1 (NFPA 54). (In Canada, the current
CAN/CGA B149 installation code). Electrical
wiring must comply with local codes. In the
absence of local codes, installation must be in
accordance with the National Electrical Code,
NFPA 70 - (latest edition). (In Canada, the current
CSA C22.1 Canadian Electric Code).

GENERAL INFORMATION

Note: Installation and repair should be per-
formed by a qualified service person. The
appliance should be inspected annually by a
qualified professional service technician. More
frequent inspections and cleanings may be
required due to excessive lint from carpeting,
bedding material, etc.
IMPORTANT
It is imperative that the control
compartment, burners and cir-
culating air passage ways of the
appliance be kept clean. See
Maintenance instructions on
Pages 5 & 6.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Due to high temperatures the appliance should
be located out of traffic and away from furniture
and draperies. Locate furniture and window
coverings accordingly.
These appliances are designed to operate on
natural or propane gas only. The use of other
fuels or combination of fuels will degrade
the performance of this system and may be
dangerous.
Millivolt Models - BTU Input
Millivolt models come standard with the manu-
ally-modulated gas valve; flame appearance and
heat output can be controlled at the gas valve.
The BTU Input for millivolt models is shown
in Tables 1 & 2:
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
BTU Input - Millivolt Models
Input (BTU) Manually-Modulated Gas
Valves (millivolt models)
NATURAL GAS
Models
Input Rate
(BTU / HR)
,000 high
SSBV-3530CNM
17,500 low
9,000 high
SSBV-4035CNM
1,500 low
Table 1
Input (BTU) Manually-Modulated Gas
Valves (millivolt models)
PROPANE GAS
Requires Field Converion
Models
Input Rate
(BTU / HR)
,000 high
SSBV-3530CPM
17,500 low
9,000 high
SSBV-4035CPM
,500 low
Table 2
Electronic Models -
Electronic models have a fixed rate gas valve.
Input of electronic models is shown in the
following table:
Electronic Models with Fixed Rate Gas Valve
Natural and Propane Gas
Model Series
Input Rate
(BTU / HR)
SSBV-3530CNE
SSBV-4035CNE
Table 3
Inlet Gas Supply Pressure
(all models)
Fuel #
Minimum
5.0" WC
Natural Gas
(1.4 kPa)
11.0" WC
Propane
(.74 kPa)
Table 4
Manifold Gas Supply Pressure
(millivolt models)
Fuel #
Low
Natural
(Lo) ." WC
Gas
(.55 kPa)
(Lo) 6." WC
(Hi) 10.0" WC
Propane
(1.57 kPa)
Table 5
,000
9,000
Maximum
10.5" WC
(.61 kPa)
1.0" WC
(. kPa)
High
(Hi) .5" WC
(.87 kPa)
(.49 kPa)