SETTING UP AND CONFIGURING THE DEVICE
To restore user defined settings for an AEP device:
1.
Locate the hole in the panel labeled RESET. The reset button is recessed into the housing.
2.
Use the pin to press in the button for between 3 to 29 seconds, then release the reset button.
If you do not press in the button long enough, the device will reset, but the user defined settings
will not be restored.
If you hold it too long (30 seconds or longer), factory default settings will be restored.
Note:
The RESET button is in the same location on all Conduit models.

Resetting the Device

You need:
A pin, paperclip, or similar thin object that can fit into the reset hole.
The following is the default condition for the RESET button on the Conduit. You can program a change to the
behavior of the button if needed.
To reset the device:
1.
Find the hole in the front panel labeled RESET. The reset button is recessed into the case.
2.
For AEP: Use the pin to press the RESET button for less than 3 seconds, then release. The device reboots.
For mLinux: Press and hold the RESET button for less than 5 seconds, then release. Holding it beyond 5
seconds resets an mLinux device to factory defaults.
3.
The status LED will keep blinking normally for a couple of seconds until the unit resets. Then the status
light will stay solid while the device reboots. Once finished, the status will resume blinking normally.

Powering Up the device

CAUTION:
Use only the power cord provided with the device. Using any other power cord voids the warranty
and can damage the device.
To power up the device:
1.
Install the desired MultiTech accessory card or cards into the slots at the back of the device. Refer to the
appropriate installation documentation for the accessory card.
2.
Connect the power cord to an outlet or power strip and to the power adapter.
3.
Connect the power adapter to the barrel jack on the back panel of the device.
4.
Verify power.
5.
Connect the device to the controlling device through the Ethernet connector or the USB connector on the
back panel.
20
The Power LED comes on immediately after power is applied.
The device takes a short time to boot up when you apply power.
®