GF55 Wood Pellet Stove
INSIDE VERTICAL INSTALLATIONS
Rain cap - ensure cap is at
least 2 feet (610mm) above
the roof at the lowest point
Storm collar
Roof flashing
Roof rafter
Fire stop with
Support Collar
Ceiling joist
Vertical vent pipe
Clean out tee with
Pipe adapter
NOTE:
All vent sections must maintian 3"
(76 mm) clearances to combustibles.
OUTSIDE VERTICAL INSTALLATIONS
6
Rain cap
24"
(61 cm)
Flashing
3" (7.5 cm)
Clearance
3"
(7.5cm)
Support
bracket
Tee with
cleanout
Type "L", "PL" or
all fuel vent
Fresh air
intake
Gas Inbuilt
HEARTH MOUNT INSTALLATION
Clean-out
Fresh-air intake
should com from
chimney. If holes
already exist fresh-air
intake can be taken
through back of the
fireplace or through
Masonry Fireplace
the ash dump.
March 2008 Product Specifi cations Book
Damper Removed
or Fastened Open
Mantel
Minimum 8" (20 cm)
from top of stove
Min 6"
(150 mm)
Floor
Protection
Combustible Floor