GF55 Wood Pellet Stove
1
/
"
9
16
(40mm)
19
7
/
"
16
(494mm)
13
/
"
1
16
(332mm)
12
/
"
9
16
(319mm)
14
5
/
"
8
(356mm)
11
7
/
"
16
(291mm)
2
GF55 Greenfi re Pellet Stove
23
1
/
"
16
(586mm)
34
/
"
1
8
(866mm)
24
/
"
7
16
(620mm)
24"
(610mm)
5
3
/
"
4
(146mm)
20
5
/
"
16
(508mm)
6
11
/
"
16
1"
(170mm)
(25mm)
Gas Inbuilt
CLEARANCES TO COMBUSTIBLES
These dimensions are minimum clearances to combustibles, however it
is highly recommended that you leave suffi cient room on each side (20"
where possible) for servicing, routine cleaning and maintenance.
This pellet stove requires fl oor protection. The fl oor protection must be
non-combustible, extending 6" (150mm) beyond the full width and depth
of the unit including 6" (150 mm) in front for ember protection.
Floor Protection:
Width
36-7/16" (934mm)
Depth
36" (914mm)
Back wall
6"
(152mm)
*NOTE: If the unit is installed as a corner installation,
clearances change from 2" to 3", see "Corner thru
Wall Installation" section.
March 2008 Product Specifi cations Book
Adjacent
3" (76mm)
wall
2"
(51mm)*

Advertisement

loading

Summary of Contents for Regency Greenfire GF55

  • Page 1 Gas Inbuilt GF55 Wood Pellet Stove GF55 Greenfi re Pellet Stove " (586mm) " (40mm) " (494mm) " (866mm) " (332mm) CLEARANCES TO COMBUSTIBLES These dimensions are minimum clearances to combustibles, however it " is highly recommended that you leave suffi cient room on each side (20" (620mm) where possible) for servicing, routine cleaning and maintenance.
  • Page 2 Gas Inbuilt GF55 Wood Pellet Stove EXHAUST AND FRESH AIR INTAKE LOCATION ALCOVE CLEARANCES EXHAUST: Base of unit to center of fl ue 20-5/16" (508mm) Minimum Width 36" (914mm) Side of unit to center of fl ue 6-11/16" (170mm) Center of unit to center of fl ue 5-3/4"...
  • Page 3: Vent Termination Requirements

    Gas Inbuilt GF55 Wood Pellet Stove VENT TERMINATION REQUIREMENTS Letter Minimum Clearance Description 24 in (61 cm) Above grass, top of plants, wood, or any other combustible materials. 48 in (122 cm) From beside/below any door or window that may be opened. 24 in (61 cm) From above any door or window that may be opened.
  • Page 4: Corner Through Wall Installation

    Gas Inbuilt GF55 Wood Pellet Stove CORNER THROUGH WALL INSTALLATION VERTICAL RISE WITH HORIZONTAL TERMINATION INSTALLATION Fresh Air Intake A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood). 3"...
  • Page 5: Inside Vertical Installations

    Gas Inbuilt GF55 Wood Pellet Stove INSIDE VERTICAL INSTALLATIONS HEARTH MOUNT INSTALLATION Rain cap - ensure cap is at least 2 feet (610mm) above the roof at the lowest point Storm collar Damper Removed or Fastened Open Roof flashing Mantel Minimum 8"...