Rinnai REU-V2632FFUG Service Manual page 30

Hide thumbs Also See for REU-V2632FFUG:
Table of Contents

Advertisement

Display Monitor Contents
No.
Contents
01
Water flow sensor recognition flow
(Example 123 = 12.3L/min).
02
Hot water Outlet thermistor temperature
(Example 20 = 20°C)
03
Hot water combustion time
(Example 6 = 600 hours)
04
Hot water operation frequency
(Example 6 = 600 Operations)
05
Hot water fan frequency
*Note 1 Fan Frequency rpm Conversion
(rpm) = (Hz) x15
06
water control connection
*Note 2 Water Control Connections
Bathroom water
Additional controller
"0
07
Water flow servo present recognising positioning
*Note 3 Water Flow Servo Positioning
Servo Position
Display
08
Inlet water temperature
(PCB recognition value)
(Example 25 = 25°C)
09
Hot water fan current flow value
(Example 6 x 10 = 60 mA)
10
Bath fill amount (this counts the litres during bath
fill operation).
11
Heat exchanger exit thermistor temperature
(Example 55 = 55°C)
12
Bypass servo present recognition positioning
(Example
250 = Half open
To return to normal operation
• Press the ON/OFF button again while holding down the Water Temperature "DOWN"
(Cooler button)
Infinity REU-V2632FFUG / HD200i REU-VM2632FFUC
Kitchen controller
1"
Open
Centre
"1"
"0"
0 = Closed
500 = Open
- 25 -
Units
Data Range
0.1L/min
0~400
°C
0~999
100 hours
000~999
100
0~999
Hz pulses/sec 0~999 *Note 1
none
0 or 1 *Note 2
Controls
connected
No
Yes
None
0~2 *Note 3
Closed
"2"
°C
0~999
10 mA
0~999
Litres
0~999
°C
0~999
Degrees
0~500
Issue 1 - 16/12/09 ©Rinnai
Display
"0"
"1"