Alcatel-Lucent 1677 SONET Link Manual page 121

Turn-up
Hide thumbs Also See for 1677 SONET Link:
Table of Contents

Advertisement

3EM13850AD
Issue 01, September 2007
On front side of LGX panel, connect fiber-optic jumper to ports corresponding to fiber-
15
optic cables from Tx and Rx port on GIGE module under test, using appropriate
jumper for connector types.
Enter
16
jumpered in step 12.
where:
AID=access identifier of GigE port.
Is LOCS set against GigE port?
17
For connection between Rx port of GIGE module and LGX panel, clean fiber-optics and
18
optical connectors (refer to DLP-117), and then retest connection. If connection still
fails test, recheck fiber-optic cable routing, replace faulty fiber-optic cable, or replace
GIGE module.
Go to step
19
Disconnect fiber-optic jumper from LGX panel.
20
Disconnect fiber-optic cables just tested from Tx port and Rx port on GIGE module.
21
Have all fiber-optic cables between all ports on all GIGE modules and LGX panel been
22
tested?
23
STOP. This procedure is complete.
Confirm Cabling Between Client-Side I/O and Customer LGX Panel (GIGE-Equipped
RTRV-COND-GIGE::AID:::LOCS;
If yes, go to step 18.
If no, go to step 20.
16
to retest connection.
If yes, go to step 23.
If no, go to step
for GigE port for which fiber-optic cables were
3
to test next fiber-optic cable.
DLP-118
4-77

Advertisement

Table of Contents
loading