Table 19. Definition of status light combinations (continued)
Operation
Cleaning Cartridge
loaded, cleaning
2
failed
Cartridge loading or
2
unloading
Unrecoverable drive
3
failure
Firmware Download
Firmware Update
Microcode Download
4
failure
5
Over Temperature
Notes:
1. If the drive completes the power-on self-test (POST) within the 2.0 second Power On LED Test time,
the POST indicator sequence is eliminated
2. A solid amber LED indicates the drive needs cleaning. The drive will continue to function, but needs
cleaning as soon as possible. A power cycle does not turn off this indicator.
3. The Fault LED will flash to indicate an unrecoverable error. An unrecoverable error is an error
condition that results in the drive not being able to function unless initiator, operator, or service
intervention is applied. An unrecoverable drive failure is usually the result of a hardware error
condition. One of the following actions will be needed to clear the flashing Fault LED:
v Hard SCSI reset
v Cartridge eject
v Power cycle
v Retry microcode download
An unrecoverable cartridge (media) failure is usually the result of a defective cartridge, media, or
cartridge state and will require the drive to eject the cartridge (if possible) to clear the flashing LED.
4. The firmware download failed and the drive is not functional. The drive boot code is in control and
the microcode download should be retried. The drive can be identified using the Inquiry command
and is bootable while in this state.
5. The Fault LED will be on solid to indicate an over-temperature condition.

Performing the internal self-test (FC 6120 or 6279)

Use the information in this topic to perform an internal self-test on your tape drive.
Prerequisites
In order to perform the test, you need the following items:
v One VXA-2 tape drive with firmware code V2123 or higher, or one VXA-320 tape drive with firmware
V3209 or higher
v One VXA cleaning cartridge X style
v One blank VXA X23 data cartridge
40
Power Systems: Managing devices
Activity
Ready
Off
Off
Flashing
On/Off
Flashing
Flashing
Flashing
Off
Off
Cleaning
Off
On
2
On
/Off
2
Off
On
/Off
2
Off
On
/Off
2
On
/Off
2
Off
On
/Off
2
Off
On
/Off
Fault
2
Off
Off
Flashing
Off
Off
Flashing
On
3
3

Advertisement