Transport; Delivery Condition; Unpacking And Handling; Energy Conservation - Viessmann EVO-COOL Series Installation And Operating Instructions Manual

Refrigeration units
Table of Contents

Advertisement

GB
2.4

Transport

The Refrigeration unit must be transported in its opera-
ting position due to oil in the compressor. For possible
further transport, only the original packaging may be
used.
2.5

Delivery condition

The refrigeration unit is delivered in a carton, operatio-
nally ready and wired for immediate plug-in.
2.6

Unpacking and handling

- Prior to and during the unpacking of the Refrigeration
unit, a visual inspection should be made in to de
termine whether possible damage has occurred during
transport.
- Please pay attention to loose parts, dents, scratches
visible oil loss, etc.
- Before disposing of the packing material, a check of it
should be made to ensure that no loose parts are
hidden in it.
- In order to process warranty claims, please provide an
exact description of the defi ciency (with picture if
possible), as well as information as to unit model
designation and serial number.
- In order to protect the unit from damage, it must only
be transported in its operating position. It must be
ensured that the evaporator and condenser units have
not been damaged. Non-compliance will result in
forfeiture of the warranty entitlement.
2.7

Energy conservation

Direct sunlight will raise the consumption of electricity.
Avoid any unnecessary or too lengthy opening of the
door.
Monitor the storage temperature.
Regularly clean the Refrigeration unit. A clean unit saves
energy and has a longer service life. Observe cleaning
intervals (see Chapter "Cleaning and maintenance of the
Refrigeration unit"). Regular maintenance increases the
service life.
General notice (liability): the details of this technical documents serve for description. Consents regarding the availability of certain features or
regarding a certain purpose always require a special written agreement.
Page 40 GB
2.8

Decommissioning

Temporary decommissioning
The refrigeration unit is decommissioned as follows:
- Turn the knob to Standby mode then press to confi rm.
- Select Standby Yes.
A signal sounds as a warning (approx. fi ve seconds) while
the system switches to the selected mode.
Check whether Standby mode is displayed on the
system:
- The current setting is displayed in the small window on
the side.
- If Yes is displayed, the system does not start up.
The current statuses of the components can be viewed in
the Information menu.
Longer-term decommissioning
The refrigeration unit is decommissioned as follows:
- Turn the knob to Standby mode then press to confirm.
- Select Standby Yes.
- If Yes is displayed, the system does not start up.
- Disconnect the refrigeration unit's mains plug to dis-
connect the refrigeration unit from the mains.
Right reserved to make technical changes!