Vitocell 300-H, EHA Series Installation

Transport and Handling

Removing panels
1. Turn tank 90° to sit across its pallet.
2. Carefully unhook front panel.
3. Remove insulation.
4. Remove spring clip and carefully pull sensor of the
thermometer out of tank cap.
5. Remove insulation ring.
6. Pull side panels forward to remove.
7. Unscrew top panel.
Note: Only for the 92 USG (350 L)
Where access to the boiler room is difficult, remove
the front and side panels unscrew the adjustable
feet and turn the DHW tank on it's side. This will
provide 2 in. less width.
8. Using a flat piece of wood and a rubber mallet,
carefully hammer inner front and rear panels off
the four corners and remove.
9. Move tank into mechanical room.
Set-up
7