15. Technical data

EVO-COOL® refrigeration units
Description
Coldroom temperature adjustment
range
Admissible ambient temperature
Size
Cooling capacity
Refrigerant
Control
Voltage / Phases / Frequency
Nominal consumption / Fuse
Dimensions (H x W x D)
Weight
1)
Noise level
EVO-COOL® deep-freeze units
Description
Coldroom temperature adjustment
range
Admissible ambient temperature
Size
Cooling capacity
Refrigerant
Control
Voltage / Phases / Frequency
Nominal consumption / Fuse
Dimensions (H x W x D)
Weight
1)
Noise level
1) A-rated equivalent sound pressure level, measured at a 10 m distance at an ambient temperature of 25°C.
According to the characteristics of the room and the installation locations, values above the specifi ed noise level can be reached.
General notice (liability): the details of this technical documents serve for description. Consents regarding the availability of certain features or
regarding a certain purpose always require a special written agreement.
Page 70 GB
CS 500
CS 900
CS 1300
1
634 W
1050 W
1350 W
230 V / 1 / 50 Hz
334 W
567 W /
660 W /
/16 A
16 A
16 A
790 x 440 x 1013 mm
45 kg
54 kg
58 kg
24,7
25,4
28,4
FS 900
FS 1200
FS 1400
1
940 W
1250 W
1410 W
230 V / 1 / 50 Hz
820 W
1145 W /
1279 W /
/16 A
16 A
16 A
790 x 440 x 1013 mm
68 kg
73 kg
75 kg
31,9
31,9
34,8
CS 1500
CS 2000
-5°C to +20°C
+1°C to +43°C
1505 W
2035 W
R134a
electronic
720 W /
1050 W /
16 A
16 A
61 kg
105 kg
27,3
33,4
FS 2000
FS 2500
-5°C to -25°C
+1°C to +43°C
2
1990 W
2490 W
R404 A
electronic
400 V / 3 / 50 Hz
1660 W /
2043 W /
16 A
16 A
996 x 640 x 1239 mm
105 kg
109 kg
35,8
37,8
Right reserved to make technical changes!
CS 2500
CS 3000
2
2440 W
3010 W
400 V / 3 / 50 Hz
1170 W /
1300 W /
16 A
16 A
996 x 640 x 1239 mm
107 kg
109 kg
39,9
37,4
FS 3000
3020 W
2496 W /
16 A
111 kg
37,5

Hide quick links: