Siemens SIMEAS Q80 Operating Instruction page 149

Power quality recorder
Table of Contents

Advertisement

Available languages

Available languages

14.1.4 Digital outputs
4 digital outputs
Parameter
channel / bits
terminal connection
insulation test voltage
electrical safety
rating /
measurement category
degree of pollution
switching time
max. switching power
switching voltage
max. switching current
contact impedance
Description of the
digital outputs of SIMEAS Q80 7KG8080
Technical specs and terminal configuration
typ.
min. / max.
4
screw terminal 14 to 24 AWG
0,2 mm² to 2,5mm²
3,6 kV
RMS
250 V / CAT III
2
5 ms
<8 ms
<1000 VA
>1 V
<250 V
DC
< 1 A
<4 A
<50 mW
.
37
Power Quality Recorder SIMEAS Q80 7KG8080, Operating instruction
Test conditions / Remarks.
mechanical closer
American Wire Gauge
for rigid and flexible lines
50 Hz Sinus; 10 sec
according EN 61010-1
according IEC 60664
min. switching voltage at 1mA
RMS
250 V~ cos j=1.0 ... 0.4
250 V~ cos j=1.0
E50417-B1074-C419-A2, Release 09.02.2011