Download Print this page

Sub-Zero 3 1 5 I Installation & Operation Manual page 19

Sub-zero i c e m a k e r 3 1 5 i, 3 1 5 i p installation & operation

Advertisement

S U B - Z E R O
M O D E L S 3 1 5 I
1)
Open the door and remove the control box
cover.
2)
Locate the cube size adjustment screw
shown in the illustration below. To make
fuller cubes, turn the screw clockwise about
1
/
turn. This will make the freezing cycle
4
longer.
3)
To shorten the freezing cycle and make
cubes that are not as full, turn the adjust-
1
ment screw
/
turn counterclockwise.
4
4)
After the next freezing cycle, the cubes
should have responded to the adjustment;
if another adjustment is required, do it early
in the freeze cycle.
S T O R A G E B I N L E V E L A D J U S T M E N T
When the ice maker shuts off, the ice level in
the storage bin should be even with the metal
tube inside the bin. If the ice in the storage bin
is too high or too low, turn the ice maker
control knob to adjust the ice storage bin
thermostat. Refer to the illustration below.
To lower the ice level, turn the knob counter-
clockwise. To increase the ice level, turn the
knob clockwise. Usually a
enough for either adjustment.
Control Knob
Ice maker control knob
A N D
3 1 5 I P
O P E R A T I O N
1
/
turn will be
8
Cube Size Adjustment
Cube size adjustment
H A R V E S T T I M E A D J U S T M E N T
The amount of harvest time may be adjusted.
It is preset from the factory at about three
minutes, which should be adequate to release
all cubes and fill the reservoir. If the timer
needs to be adjusted, follow these steps:
1)
Unplug the ice maker or disconnect the
electrical power.
2)
Remove the kickplate/grille.
3)
Remove the control box cover.
4)
Locate the timer shown in the illustration
below. Loosen the set screw that holds the
two halves of the timer cam together.
5)
Rotate one half of the cam to open or close
the lower portion of the cam. More of an
opening equals more harvest time and less
of an opening means less harvest time.
6)
Tighten the set-screw.
7)
Replace the control box cover and kickplate/
grille.
8)
Reconnect the electrical power.
Electrical Shock Hazard—Disconnect
electrical power before beginning
removal of parts.
Harvest time adjustment
19

Hide quick links:

Advertisement

loading

This manual is also suitable for:

31513151p