Summary of Contents for Sub-Zero UC-15I

  • Page 1 N D E R C O U N T E R A C H I N E & O NSTALLATION PERATION...
  • Page 2: Table Of Contents

    Another footnote we would like to identify is IMPORTANT NOTE: This highlights informa- tion that is especially relevant to a problem- free installation. ® SUB-ZERO is a registered trademark of Sub-Zero, Inc.
  • Page 3 800-222-7820 or visit our website to validate the installation date. If you do not at subzero.com. return your product registration card, Sub-Zero will use the date of sale to the Sub-Zero dealer as the first day of warranty coverage for your new ice machine.
  • Page 4: Ice Machine Installation

    I N S TA L L AT I O N I C E M AC H I N E R E Q U I R E M E N T S Models UC-15I and UC-15IO must have open site (gravity) drain available Proper installation requires connection to (see page 8).
  • Page 5 I N S T A L L AT I O N O V E R A L L D I M E N S I O N S Models UC-15I, UC-15IP, UC-15IO & UC-15IPO A L L M O D E L S "...
  • Page 6 Service diagnostics are finishing work is completed. performed from the top of the ice machine. Models UC-15I and UC-15IO are gravity drain The location must be free of airborne and models that require a drain tube that is other contaminants.
  • Page 7 S U B - Z E R O I C E M AC H I N E I N S T A L L AT I O N E L E C T R I C A L R E Q U I R E M E N T S Prepare electrical circuit before installation of IMPORTANT NOTE: Observe correct your ice machine.
  • Page 8 I M P O R T A N T Drain lines must have a 1 " drop per 5 Models UC-15I and UC-15IO are supplied with N O T E feet of run (2.5 cm per meter), and must a drain hose for gravity draining. The optional not create traps.
  • Page 9 80˚F (27˚C) Max. 80 psi (551.5 kPA) Max. Copper Tubing inside diameter N O T E Water Outlet " (19) " (19) minimum UC-15I and — — Hose Barb inside diameter Plumbing must UC-15IO conform to state and local codes.
  • Page 10 S U B - Z E R O I C E M AC H I N E I N S TA L L AT I O N I N S TA L L AT I O N I N S TA L L AT I O N P R O C E D U R E Open the shut-off valve on the water line.
  • Page 11 S U B - Z E R O I C E M AC H I N E I N S T A L L AT I O N I N S TA L L AT I O N Prepare sanitizer solution and sanitize the ice machine according to In Place Do not cover the kickplate area.
  • Page 12 The hinged side of the door may be reversed to the other side if desired. Move the bin into its final position. The Sub-Zero ice machine is shipped with the Level the ice machine to assure that the bin door hinged at the right. The door and hinges door closes and seals properly.
  • Page 13 S U B - Z E R O I C E M AC H I N E I N S T A L L AT I O N I N S TA L L AT I O N Remove the upper plastic trim piece (right Remove four screws from the front top rail.
  • Page 14 If you have questions, contact your scratched or damaged. Sub-Zero dealer or cabinet supplier. Instruc- P A N E L tions regarding sizing of the door panel are D E S I G N Position the template provided flush with the provided in the Sub-Zero design guide.
  • Page 15 9 0 - D E G R E E D O O R S T O P Exercise caution when drilling holes for The Sub-Zero ice machine has a 90-degree mounting hardware. This is especially door stop. Follow these steps for installation: critical with inset panels.
  • Page 16: Installation Checklist

    Any questions or problems about the installa- instructions for pump units? I N F O R M AT I O N tion should be directed to your Sub-Zero Has the owner/operator been instructed dealer or Sub-Zero customer service at regarding maintenance and the use of Sub-Zero 800-222-7820.
  • Page 17: Ice Machine Features

    I C E M AC H I N E F E AT U R E S Undercounter ice machine Automatic defrost Models UC-15I and UC-15IO have a gravity Reversible door swing drain, while Models UC-15IP and UC-15IPO Front venting with removable kickplate...
  • Page 18 S U B - Z E R O I C E M AC H I N E O P E R AT I O N B E F O R E S TA RT I N G T H E I C E M A C H I N E S A N I T I Z E Do not operate equipment that has been It is important to clean and sanitize the ice...
  • Page 19 S U B - Z E R O I C E M AC H I N E O P E R AT I O N C O N T R O L P A N E L F U N C T I O N S CLEAN Button (Green) Pressing the CLEAN button will initiate a clean POWER Button (Green)
  • Page 20 O P E R AT I O N A L C H E C K S Depending on ambient conditions and cold Sub-Zero ice machines are factory-operated water supply temperature, the ice making and adjusted before shipment. Normally, new process will take approximately 30 minutes.
  • Page 21 S U B - Z E R O I C E M AC H I N E O P E R AT I O N O P E R AT I O N A L C H E C K S T E S T I N G A N D A D J U S T I N G T H E If the ice machine stops before the bin is full or B I N T H E R M O S T AT...
  • Page 22 S U B - Z E R O I C E M AC H I N E O P E R AT I O N O P E R AT I O N A L C H E C K S C U B E W E I G H T A D J U S T M E N T Adjusting finishing time: Adjust in 1 minute increments and allow the...
  • Page 23 C A R E C L E A N I N G You are responsible for maintaining the ice To ensure efficient operation, Sub-Zero recom- machine in accordance with the instructions in mends an annual cleaning performed by a this manual. Maintenance procedures are not qualified service company.
  • Page 24 S U B - Z E R O I C E M AC H I N E C A R E E X T E R I O R C L E A N I N G C L E A N I N G T H E C O N D E N S E R Clean the area around the ice machine as often as necessary to maintain cleanliness and effi-...
  • Page 25 Use only Sub-Zero approved ice machine cleaner The ice machine will automatically time out (7013031) and sanitizer (7013033) only. a ten minute cleaning cycle, followed by eight rinse cycles, and stop.
  • Page 26 S U B - Z E R O I C E M AC H I N E C A R E WAT E R F I LT E R R E P L A C E M E N T To replace the water filter incoming water does not need to be turned off.
  • Page 27 S U B - Z E R O I C E M AC H I N E C A R E I C E M A C H I N E M A I N T E N A N C E R E M O V A L F R O M S E R V I C E , L O N G T E R M Follow the procedure below.
  • Page 28: Ice Machine Operation

    Ambient temperature is too high Ambient temperature must be or low between 50˚F and 100˚F (10˚C and 38˚C) for models UC-15I and UC-15IP, and between 50˚F and 110˚F (10˚C and 43˚C) for models UC-15IO and UC-15IPO. Water filter is clogged Complete semi-annual maintenance, refer page 23.
  • Page 29 Dirty condenser Clean condenser, see page 24. High air temperature entering Air temperature must not exceed condenser 100˚F (38˚C) for models UC-15I and UC-15IP, and 110˚F (43˚C) for models UC-15IO and UC-15IPO. Water filtration is poor Replace the filter. Water inlet valve stuck open Turn off ice machine.
  • Page 30: Service Information

    P R O D U C T R E G I S T R AT I O N model and serial number of your unit when Register your new Sub-Zero today so that we you call. You’ll find these numbers on the may ensure your satisfaction.
  • Page 31 FULL FIVE YEAR SEALED SYSTEM WARRANTY For five years from the date of original installation, your Sub-Zero warranty covers all parts and labor to repair or replace any components that prove to be defective in materials or workmanship in the sealed system. The sealed system consists of the compressor, condenser, evaporator, drier and all connecting tubing.
  • Page 32 S U B - Z E R O , I N C . P. O . B O X 4 4 1 3 0 M A D I S O N , W I 5 3 7 4 4 - 4 1 3 0 8 0 0 - 2 2 2 - 7 8 2 0 S U B Z E R O .

This manual is also suitable for: