Configuration
6.2 Establishing a connection to the CMR
Calling up the start page of the CMR
● In the address line of the browser, enter the IP address of the CMR in full.
In the factory setting, the IP address is: http://192.168.0.3
Entering the user name and password
1. You will be prompted to enter the user name and the password.
The factory setting is as follows:
User name: admin
Password: admin
2. After you log in the first time, you will be prompted to change your password.
Keep to the basic rules for a secure password (refer to the notes in the WBM)
The start page is displayed
After entering the user name and password, the start page of the CMR opens in the Web
browser. The start page provides an overview of the operating status of the device.
The start page is not displayed
If, after several attempts, the browser still reports that the page cannot be displayed, try the
following:
Checking the hardware connection
1. Open the DOS command prompt by selecting the menu command "Start" > "Programs" >
"Accessories" > "Command Prompt".
Result: The "Command Prompt" window appears.
2. Enter the command "ping 192.168.0.3".
When operating correctly, you will receive four replies within a few seconds.
If you do not receive four replies within a few seconds:
● Check whether the network cable, the connectors and the network adapter are correctly
connected.
Do not use a proxy server
Follow the steps outlined below depending on the operating system:
1. Select the "Tools" > "Internet Options" menu command.
2. Select the "Connections" tab.
3. Click the "LAN settings" button.
The "Local Area Network Settings" dialog opens.
4. Under the "Proxy server" entry, disable the "Use a proxy server for your LAN" check box.
50