PROGRAMMING & FEATURES
CompleteStat
CS9B-THOA
CS9B-THOCA
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
www.bardhvac.com
ADVANCED
TM
Models:
CS9BE-THOA
CS9BE-THOCA
Controller
Manual:
Supersedes:
Date:
2100-685
NEW
3-20-18
Page
1 of 18

Advertisement

Table of Contents
loading

Summary of Contents for Bard CompleteStat CS9B-THOA

  • Page 1 ADVANCED PROGRAMMING & FEATURES CompleteStat Controller Models: CS9B-THOA CS9BE-THOA CS9B-THOCA CS9BE-THOCA Bard Manufacturing Company, Inc. Manual: 2100-685 Bryan, Ohio 43506 Supersedes: Date: 3-20-18 www.bardhvac.com Page 1 of 18...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION ............3 FIGURES Display Options ..........3 Figure 1 CompleteStat Home Screen Features ..3 Figure 2 User Interface (Display) Option ..... 3 BASIC OPERATION ..........5 Figure 3 Motion/Occupancy Sensor Detection Operational Overviews ......... 5 Range ..........4 Setting Date/Time ..........
  • Page 3: Installation

    3. Controller will ask for password. Press UP and RIGHT 5 seconds. These values can be customized if desired. buttons to enter ‘BARD’. Press ENTER button. NOTE: By default, controller will read temperature in 4. Press DOWN button to scroll to ADVANCED. Press Fahrenheit.
  • Page 4: Range

    FIGURE 3 • ROTATION VALUES – Choose to HIDE or Motion/Occupancy Sensor Detection Range SHOW: HUM (SHOW*) OAT (HIDE*) U13 (SHOW*) – Non-CO sensing models C02 (SHOW*) – CO sensing models UI4 (HIDE*) • SHOW TEMP TENTHS – Choose YES (allows decimal temperature measurement) or NO* •...
  • Page 5: Basic Operation

    BASIC OPERATION Operational Overviews mode enabling “setback” temperatures and disabling ventilation unless the controller senses motion. After The factory-default settings will provide an intelligent, sensing motion, the controller will enter a Temporary “learning” temperature control. Override (OVR) mode and will maintain “occupied” temperatures and enable ventilation based upon CO CS9B(E)-THOA (non-CO sensing capability) models...
  • Page 6: Scheduling

    FIGURE 5 6. Press DOWN button to scroll to TIME. Press ENTER button. Scheduling Options 7. Press RIGHT, UP or DOWN buttons to adjust SCHEDULE existing hour, minute, second and/or AM/PM. ENTIRE WEEK [MON-SUN] 8. Press ENTER button to save selection(s). WEEKDAYS [MON-FRI] WEEKEND [SAT-SUN] 9.
  • Page 7: Adjusting Standby Conditions

    OVR will already be displayed in the “Occupancy Status” line. 3. Controller will ask for password. Press UP and RIGHT buttons to enter ‘BARD’. Press ENTER button. To cancel temporary override from Home screen: 4. Press ENTER button again to select APPLICATION.
  • Page 8: Staging Delay

    OCC OVRIDE (MINS): 3. Controller will ask for password. Press UP and RIGHT SCHEDULE buttons to enter ‘BARD’. Press ENTER button. 4. Press ENTER button again to select APPLICATION. 5. Press DOWN button to scroll to ADDITIONAL SETUP. Press ENTER button.
  • Page 9: Remote Occupancy Sensor

    Press ENTER button. 10. Press LEFT button to return to the Home screen. 3. Controller will ask for password. Press UP and RIGHT buttons to enter ‘BARD’. Press ENTER button. Leaving Air Temperature Sensor 4. Press ENTER button again to select APPLICATION.
  • Page 10: Temperature Limits

    Absolute limits can be set to ensure no user can raise/ 3. Controller will ask for password. Press UP and RIGHT lower occupied or unoccupied temperatures past buttons to enter ‘BARD’. Press ENTER button. specific setpoints, or that setpoints cross specific minimum differential margins.
  • Page 11: Indoor Blower Settings

    FIGURE 13 Minimum Setpoint Differential & Heating/Cooling Proportional Bands FIGURE 14 • UNOCC Adjusting Heating/Cooling Proportional Bands ON: System fan will run continuously during and Integers all operational modes AUTO: System fan will operate during call for LOOP CONFIGURATION cooling or heating, but will cycle off when no COOL PROP: 2.0°F compressor or no heating is needed (Default).
  • Page 12: Alarms Feature

    2. Press DOWN button to scroll to TECHNICIAN. Press ENTER button. 3. Controller will ask for password. Press UP and RIGHT buttons to enter ‘BARD’. Press ENTER button. 14. Press ENTER button to select appropriate choice. 4. Press DOWN button to scroll to ALARMS. Press 15.
  • Page 13: Security Settings

    2. Press DOWN button to scroll to TECHNICIAN. FIGURE 19 Press ENTER button. Alarm Details 3. Controller will ask for password. Press UP and RIGHT buttons to enter ‘BARD’. Press ENTER button. MON 12/12 7 27 AM 4. Press DOWN button to scroll to ADVANCED. Press HEAT: °F...
  • Page 14: Trend Logs

    Press ENTER button. FAN OCC/UNOCC: USER 3. Controller will ask for password. Press UP and RIGHT buttons to enter ‘BARD’. Press ENTER button. 4. Press UP or DOWN buttons to scroll to ADVANCED To access/change passwords from the Home screen: Press ENTER button.
  • Page 15: Restart

    2. Press DOWN button to scroll to TECHNICIAN. Press ENTER button. • BV1 – 3. Controller will ask for password. Press UP and RIGHT buttons to enter ‘BARD’. Press ENTER button. • BO1 – 4. Press UP or DOWN buttons to scroll to TREND •...
  • Page 16: Restore Factory Settings

    To initiate a restart from the Home screen: BACnet Communications 1. Press RIGHT button to access Main Menu screen. The Bard CompleteStat is a native BACnet Advanced Application Controller (B-AAC) and can simplify 2. Press DOWN button to scroll to TECHNICIAN.
  • Page 17: Advanced Time Settings For Bacnet Applications

    3. Controller will ask for password. Press UP and RIGHT play, and the MAC address is not changeable. buttons to enter ‘BARD’. Press ENTER button. To access the device instance, name and location from 4. Press DOWN button to scroll to ADVANCED. Press the Home screen: ENTER button.
  • Page 18: Temperature Sensor Calibration

    2. Press DOWN button to scroll to TECHNICIAN. Press ENTER button. 3. Controller will ask for password. Press UP and RIGHT buttons to enter ‘BARD’. Press ENTER button. 4. Press DOWN button to scroll to ADVANCED. Press ENTER button. 5. Press UP or DOWN buttons to scroll to INPUTS.