Air to water heat pump. split system (single phase type). split system (3-phase type).
Table of Contents

Advertisement

Split system (Single phase and 3-phase type)
Thermistor (Discharge)
Thermistor (comp. Temp.)
Remove the Thermistor (comp. temp.)
and the Thermistor (Discharge).
Remove the COMP BOLTS.
(3 places)
Range
Cut the Discharge pipe in this range
 Keep their shape better.
 There is a possibility of catching fire to oil when removing by the welding without cutting it.
Maintenance Document 1544-1
Cut the binder, and remove
the heat insulation.
Range
Cut the Suction pipe in this range.
Remove the COMPRESSOR.
Remove the Thermistor (Discharge).
Cut the Injection port in this range
Range
111