Displaying actual values
Use / to scan the following actual val-
ues subject to the system equipment
level:
Note
The flashing sensor symbol in the sys-
tem scheme shows the position of the
actual temperature.
KOL – Collector temperature in °C
(standard display)
■ TSPU – DHW temperature in °C
■ S3 – Thermostat temperature in °C,
temperature at any additional connec-
ted sensor that may be connected
■ n1% – Solar circuit pump speed
■ n2% – Operating condition of the
actuator at relay output R2
■ hP1 – Hours run of the equipment at
relay output 1
■ hP2 – Hours run of the equipment at
relay output 2
■ KWh – Amount of heat in kWh, if the
heat meter is enabled
■ MWh – Amount of heat in MWh, if the
heat meter is enabled
Note
Add the values for MWh and kWh
together.
Resetting hours run and amount of
heat
Whilst the value is displayed, press the
following keys:
1. OK "SET" flashes. Value 0
appears.
2. OK to confirm

Scanning options

7