Ten Foot Rule Summary - Superior ST-1 Series Installation Instructions Manual

Table of Contents

Advertisement

TFl O.CT2
Termination
Figure
37
Uslng a CT2
Chase
Terrnlnatlon
Reler to spedCc installation instnxtions induded
with the CT2 chase termination for clearance stat-
ments and installation details.
Using a CTDT Chase Termination
Refer to
speak
instalation instmctians induded
with the CTDT c h m termination.
Note:
/ I
is m m e n d e d that allexterior exposed
related metallireplace mmponenls, wch as termi-
nations, flashings, storm collars andlor flue be
painted
wirh
a premium qualily, high temperalure,
us1 preventatbe painl designid for metai. Thb is
espedally important when instaliations aremade in
1
abnormalbadversawmiveenvinnments~such
as nearkes, oceans win areas with consislent/y
high humidiiy mndaions. Consuit the paint manu-
factures inshudions for
p w r
preparation and
application.
/
TEN
FOOT
RULE SUMMARY
The minimum chimney height above the r w l and1
or to adjacent wails and buildings is specified by
all
I
major building d e s .
'I :he ho~zontal
d
stance 'rom the wak of the roo1
stesslnen
10' (3m).Inetopotthechimneymust be
at least
1 '
i6lOmml amve the peak 01 the rwl.
If the horizontal distance from the chimney edge to
thepeakoftherwfkmorethan 10'(3m)achimney
height reference pdnt is established on the roof
surface 10' (3m) horizontally from the chimney
edge. The lop of the chimney must be at least 2
(610mm) above this reference point. In all cases,
the chimney cannot be less then
5
(914mm) above
the roof at the edge of the chimney.
"Note:
2" (51mmJ
air
space lo combuslibles
required
when
Installing Model ST-3840-1 In
10
Canada.
Figure 38
7
Min
The
2
in 10' ,ule is necessary in the interest of
salety bu! does not ensure smokefree operation.
Trees, buildings, adjoining rwf lines, adverse wind
conditions. etc., may requireatallerchimney should
the fireplace not draR properly (Figure 38).
If more than one termination islocsted in thesame
chase or wilhin !he same general proximity, we
suggest they should
be
separated in distance at
least 24' (610mm) horizontally from flue center lo
flue center and stacked or staggered venically at
least 18' (457mm) apart, from the termination of
one smoke exit tothetermination of another smoke
exit (figure 39).
TFICCTO
Figure 39
Thissuggestion is provided in theinterest of better
operation. If the terminations are located too close
toeachother,smokemay migratelromoneflueinto
the other.
TFlO
CHIMNEY COMPONENT
CALCULATIONS
The minimum installed height ol the ST-1 series
lireplace sptem (including lireplace and chimney
mmponenls)
is 15'0'
j4.57m).
The
maximum sys-
tem height is 44'0' (13.41 m).
Todelerminethe number of chimney sedbns and
chimney components required, followthesestep:
I. Determine total vertical height ol the fireplaca
installation. This dimension is thedistance from the
surface the teplace sets on to the point where
smoke exns lrom the termination.
NOTE OIAGllAUS&
i L LUSTRl n ONSNOTTOSCl i E
2. Determine the number of chimney mmponents
required, except chknney sedbns. This would
indude lirestop spacers, dabilizers, roo1 flashing,
eIc.
3. The elfective heights of the components are:
ST-1 Fireplace
=
57 114'
)
(1454mm)
CTD Termination
=
4'
(102mm)
CT1 Termination
=
18'
(4nmm)
CT2 Terminalion
=
15' to 23'
(381mm to 584mm)
S4 Stabilizer'
-
2112'
(64mm)'
Required for every 30' (9.1 m) at verlical chimney
and 10'01 onset chimney.
4.
Detmineamountofchimney height requiredby
subtractino total mmbined heiaht of
all re selected
mmponen"ts (fireplace and ch;mney mmponents
lrom total desired he~ght.)
Relerence Vertical Etevalion
Chart and
determine
thenumberolchimneyseclions(quanl~andlength)
required.
i