Power supply connection

6.3.1

Requirements for the power supply

Pin assignment
Table 6- 2
Pin
1
2
3
External 24 V power supply
Interface X1 is intended exclusively for the connection of the external 24 V power supply,
e.g.
● SITOP,
● CSM = Control Supply Module (see the Manual SINAMICS S120 Power Units Booksize).
The following power consumption values for the PPU provide a configuration basis for
calculating the 24 V DC power supply.
Table 6- 3
Parameter
Typ. power consumption
Max. power consumption
Max. starting current
PPU only (processor, memory, etc.)
1)
PPU with full load (USB, handwheels)
2)
Requirements of DC power supplies
In the case of supply lines > 10 m, protectors must be installed at the device input in order
to protect against lightning (surge).
The DC power supply must be connected to the ground/shield of the control unit for EMC
and/or functional reasons. For EMC reasons, this connection should only be made at one
point. As a rule, the connection is provided as standard in the PLC I/Os. In exceptional
circumstances when this is not the case, the ground connection should be made on the
grounding rail of the control cabinet; please also refer to /EMC/EMC Installation Guide.
PPU
Manual, 11/2010, 6FC5397-2DP10-1BA0
Pin assignment at X1 screw-type terminal block
Signal name
P24
M
PE
Input voltage specification
1)
2)
DANGER
Signal type
Meaning
VI
24 V DC power supply
VO
Ground
GND
Protective ground
Values
1.2 A
2.5 A
4.4 A
Connecting
6.3 Power supply connection
63