P/N 0515297_E
TEMPERATURE ADJUSTMENT
1. Rotate the adjustment knob counter clock-
wise for a hammer setpoint or clockwise for
a colder setpoint.
2. While adjusting the temperature, the display
shows the setpoint (cut out value). A few
seconds after the temperature is set, the
controller reverts to the sensed temperature
in the merchandiser.
3. To verify merchandiser settings, perform the
operations below. Output readings should
be within one degree of the temperatures
shown above.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
The control has protective settings to prevent
short cycling of the compressor.
A. The compressor may run for up to 3 min.
after Step 2 is completed. Start the 10 sec.
count down for Step 3, once the display is
blank.
B. The defrost initiation may be delayed for up
to 6 min. after Step 3 is completed.
The display will show the temperature prior to
defrost once Step 3 is completed, even with the
protective delay timing out. The temperature
will be locked for 1 hour after defrost has
terminated to allow the temperature to
stabilize.
3-7
HGM Merchandisers