General
The heating output will be determined by the fan
speed. You can modify the heating output by
changing the fan speed in accordance with the
setting values listed in table "Output adjustment".
Lower output
limit
.
Press both programming keys (+) and (-)
simultaneously;the display will show "a.".
.
With key(+) selectparameter no. 2forthe lower
output Iimit.
.
Pressreset key;the factory-set parametervalue
accordingto thetable belowwi IIthen bedisplayed.
.
Changethe parameterwith the (+) or (-) key.
.
Pressthe reset key; the modified value will be
adopted, and the display will again show the
heating water flow temperature.Thisterminates
the adjustment of the lower output.
Upper output limit
.
Press both programming keys (+) and (-)
simultaneously;the display will show "a.".
.
With key(+),selectparameter no. 3forthe upper
output limit of
DHW cylinder loading or
parameter no. 4 for heating mode.
.
Pressreset key;the factory-set parametervalue
accordingtothetable belowwill then bedisplayed.
.
Changethe parameterwith the (+) or (-) key.
.
Pressthe reset key; the modified value will be
adopted and the display will again show the
heating water flow temperature.Thisterminates
the adjustment of the upper output.
Changing
the output
Resetbutton
(-)
(+)
Programmingkeys
Fig.: Control unit display
Table:
Output adjustment
TGB-40
Table:
Output adjustment TGB-60
~
-eating
23