Limiting The Maximum Output - Wolf MGK-130 Technical Manual And Installation Instructions

Gas condensing boilers
Table of Contents

Advertisement

MGK-130 / MGK-170 / MGK-210 / MGK-250 / MGK-300
Output setting (parameter GB04)
The output setting can be modified with Wolf control accessories with eBUS capability.
The heating output will be determined by the gas fan speed. By reducing the gas fan speed in accordance with the
table, the maximum output will be matched at 80/60 °C to natural gas H.
MGK-130
Output (kW)
Display value (%)
MGK-170
Output (kW)
Display value (%)
MGK 210
Output (kW)
Display value (%)
MGK 250
Output (kW)
Display value (%)
MGK-300
Output (kW)
Display value (%)
Table: Output setting
Limiting the maximum output relative to a flow/return temperature of 80/60 °C
Settings for parameter GB04 with eBUS-enabled Wolf connection accessories in [%]
26

Limiting the maximum output

23
31
38
46
20
25
29
34
27
40
50
60
20
28
34
40
34
40
55
20
23
30
40
55
70
85
20
26
32
38
45
62
79
97
20
27
34
41
53
61
68
76
38
43
47
52
70
80
90
100
46
52
58
64
70
85
100
115
37
45
52
59
100
115
130
145
44
50
56
62
114
131
148
165
47
54
61
68
83
91
99
106
56
61
65
70
110
120
130
140
70
76
82
88
130
145
160
175
66
73
81
88
160
175
190
205
68
74
80
86
182
200
217
234
75
82
89
96
114
121
75
100
150
160
94
100
190
200
95
100
220
240
92
100
251
275
102
100
3062880_0910

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mgk-170Mgk-250Mgk-300Mgk-210

Table of Contents