Summary of Contents for Nasco Life/Form ADULT CRiSis LF03965U

  • Page 1 ADULT AUSCULTATION CRiSis™ SYSTEM MANIKIN LF03965U INSTRUCTION MANUAL NOTE: This product contains dry natural rubber. Products by NASCO...
  • Page 2: Limited Warranty

    NASCO will repair any defect reported within three years of the date of purchase at no charge. Products found to be defective may be returned to...
  • Page 3: List Of Components

    The CRiSis™ Auscultation Manikin is a NOTE: Avoid using cleaner around the mouth area if students will be applying direct mouth- Complete Resuscitation System that to-mouth resuscitation techniques, as the allows training of CPR, airway manage- cleaner may be toxic if ingested. NEVER place ment, IV therapy, blood pressure read- the trainer on any kind of printed paper or ings, defibrillation, and auscultation of...
  • Page 4 NOTE: NASCO recommends the use of the provided lubricant or a similar veg- NASCO has taken great care to create etable-based lubricant for the Airway an airway management trainer that is Management Trainer head. The use of a...
  • Page 5 Figure 3 Figure 5 2. Remove the lung bags from the 4. Place the lung bags through the upper compression plate. Connect hole in the center of the upper com- the right and left lung bags to the pression plate so they rest on top of adapters in the right and left bronchi the plate (Figure 6).
  • Page 6 To rinse the airway, follow the same pro- Airway Management Trainer Head: cedure using clean, warm tap water. LF03285U Replacement Lungs LF03644U NASCO Pump Spray Lubricant Repeat this process until all the soap has W09919U REN Cleaner been flushed from the system.
  • Page 7 The Skin and Vein Kits are avail- able through NASCO (see page 9 for list of supplies). Internal Structure: Internally, the vascular structure (rubber...
  • Page 8 Figure 5 B. Preparing the Arm for Figure 4 Intravenous Infusions 1. Close the clamp at the end of IV 3. Be sure the clamp on the IV tubing is bag A tube, then fill with water (dis- closed, and hang the bag no more tilled water is recommended), and than 18"...
  • Page 9 2. Intravenous infusion — insert butter- fly into lumen of vein. Proof of cor- rect insertion is evidenced by flash- back of “blood.” Insert end of IV tubing into butterfly. Adjust flow to desirable rate with clamp. With this arrangement the IV bag B, when full, Figure 6 may be easily switched with A.
  • Page 10 Return syn- thetic blood to the storage bottle. 8. NASCO Vein Tubing Sealant Kit Remove pinch clamps and IV sets from (LF01099U) will extend the life of arm. Use tap water to flush the venous the tubing.
  • Page 11 Blood Pressure Simulator bottom of the bracket. It is recommended About the Simulator… that alkaline batteries be used for The NASCO Life/form Blood Pressure ® increased battery life. After the batteries Simulator is designed for years of mainte-...
  • Page 12 (See figure 6.) The diastolic pressure is set by pressing the Palpable pulse feature Menu key a second time. Adjust the setting The NASCO Life/form Blood Pressure up and down with the arrow up or down ®...
  • Page 13 1 (the lowest ed so that the trainee can become famil- volume) to level 7 (the highest volume). iar with this phenomenon. Using the NASCO Life/form ® Blood Pressure Simulator First, verify that the pressure line tubing...
  • Page 14 If the auscultatory gap up as described in the section titled had been selected, then an absence of an audible pulse would have b e e n “Using The NASCO Life/form Blood ® noticed during what would have been Pressure Simulator.”...
  • Page 15 “Calibration T-fitting included with the simulator, which Procedures” and calibrate the unit. When is also available through your NASCO the calibration procedures have been catalog sales office. Using a wire cutting completed, the simulator is ready for use.
  • Page 16 All nor- mal safety precautions for defibrillation train- ing should be followed and energy levels should be minimized. NASCO did not design nor intend this Defibrillation Chest Skin to be used as anything other than a training appa- ratus for defibrillation.
  • Page 17 — Pad and Patient the same ones you use on patients. In an Simulator Adapter effort to help you save money, NASCO Package does offer a set of defibrillation pad and patient simulator adapters that will corre-...
  • Page 18 About the Auscultation Simulator: The remote control can be programmed to The Life/form Auscultation Trainer Simulator ® these lung conditions: duplicates heart and lung conditions selected 01 Normal Lung by the instructor by wireless remote control. 02 Normal Vesicular The student must palpate to identify the correct 03 Wheezes auscultation sites and will hear different heart 04 Mono wheeze...
  • Page 19 Manikin LF03603U Adult Airway Management Head Only LF03609U Child Airway Management Trainer Fort Atkinson 901 Janesville Avenue, P .O. Box 901 Fort Atkinson, Wisconsin 53538-0901 1-800-558-9595 www.eNASCO.com • E-mail: lifeform@eNASCO.com COPYRIGHT © NASCO 1998 PRINTED IN U.S.A. NP 86-98/RV 8-03...