Summary of Contents for Nasco LF03500U

  • Page 1 HEALTHCARE Adult Airway Decontamination Simulator LF03500U INSTRUCTION MANUAL 5-Year Warranty WARNING: Products may contain dry natural rubber.
  • Page 3: List Of Components

    ABOUT THE SIMULATOR Simple modifications to the existing “Airway Larry” allow for a new aspect in training airway management. The Adult Life/form ® Airway Decontamination or Suction Assisted Laryngoscopy and Airway Decontamination (S.A.L.A.D) Simulator, developed in partnership with Dr. James DuCanto, Director of Simulation Center for Aurora St. Luke’s Medical Center in Milwaukee, WI, uses suction to enhance first pass success-laryngoscopy FPS-L with a non-anesthetized patient in active emesis.
  • Page 4 Figure 1 Figure 2 SETUP A. Installing the Head 1. Remove the head and supplies from the case. Retain any packaging for future use. 2. Using the #10 Spanner Bit, remove the safety cap from the case. 3. With the face of the manikin facing down, feed the esopha- gus and trachea tubes through the hole in the case.
  • Page 5 • 3 quarts/liters of water to 9 tbsp./135 ml of cellulose Note: Nasco recommends using distilled water for the mixing procedures. White vinegar could also be used in place of distilled water. 1. Stir, mix, and/or shake vigorously for approx- imately 2 minutes, or until completely mixed.
  • Page 6 Nasco lubricant provided. (See Figure 11.) Note: Depressing the hand pump allows for approxi- mately 1 tbsp./15 ml of simulated emesis per pump.
  • Page 7: Care And Maintenance

    4. Remove the lungs and tubing connected to the C. Intubating the Airway Management Trainer esophagus. Nasco recommends the use of a 7.5-8 mm endotracheal tube Remove the head from the case using the same for oral intubation and 7.5 cm or smaller for nasal intubation.
  • Page 8: Supplies/Replacement Parts

    Nasco for repair. • Ensure trainer and all of the supplies are thoroughly cleaned and dry prior to storage. Actual product may vary slightly from photo. Nasco Healthcare reserves the right to change product color, materials, supplies, or function as needed.
  • Page 9 Other Available Simulators LF00994U Cricothyrotomy Simulator LF03623U Infant Airway Management Trainer with Stand LF03633U Child Airway Management Trainer Torso LF03672U “Airway Larry” with Electronic Connections LF03685U Advanced “Airway Larry” Airway Management Trainer with Stand LF03830U Adult Intraosseous Infusion Simulator LF03685U LF03672U LF03633U LF03623U...