Nx10/15 Wiring - Siemens SINUMERIK 840D sl Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Rules for DRIVE-CLiQ sockets
The following rules must be observed when using DRIVE-CLiQ sockets:
● The control unit must be connected to X200 on the first booksize power unit after it.
● The DRIVE-CLiQ lines between each of the power units should be connected from
● The power line to the motor and the associated motor encoder must be connected to a
Figure 5-16
DRIVE-CLiQ wiring
Miscellaneous
If an additional encoder is connected to a Motor Module, it is automatically assigned to this
drive as encoder 2.
5.5.2

NX10/15 Wiring

NX10/15 DRIVE-CLiQ topology
NX10/15 components can be connected to the control unit via DRIVE-CLiQ. The following
rules apply to wiring of the NX10/15:
● Only one star topology is permitted between the NX10/15 and the control unit. This
● DRIVE-CLiQ ports not assigned to NX10/15 can be wired to other DRIVE-CLiQ
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
interface X201 to X200 on the next component.
Motor Module. The motor encoder is connected via terminal X202 or X203 on Double
Motor Modules.
means that only one NX10/15 can be operated per DRIVE-CLiQ port on a control unit.
components.
Connection of the Components
5.5 DRIVE-CLiQ Topologies
5-39