Komatsu 930E-2 Shop Manual page 173

Dump truck w/ cummins qsk60 engine
Table of Contents

Advertisement

EVENT
DESCRIPTION
NUMBER
:05
high dc buss when running
:06
high dc buss after pc powerup
:07
blower control fault
:08
high dc buss when running
overcurrent after pc powerup, current
:09
overload
:10
current overload
:11
low dc buss overcurrent
:12
low dc buss current overload
:13
gate drive trip
:14
no input voltage
637
AUX DC LINK HOT
691
PSC COMM. FAULT
:01
missing message
:02
bad tick
:03
bad CRC
:04
FIFO overflow
:05
bad start bit
:06
bad stop bit
:07
message error
696
UNEXPECTED TCI CPU RESET
698
DATA STORE
699
SOFTWARE ERROR
E02014 3/01
TABLE IV: DID PANEL FAULT CODES (Cont.)
EVENT
EVENT
RESTRICTION
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Electrical Propulsion System Components
DETECTION
INFORMATION
High dc bus voltage detected during
operation.
High dc bus voltage detected after
phase controller powerup.
Fault detected after phase controller
powerup.
High dc bus voltage detected during
operation.
Overcurrent condition detected after
phase controller power up.
Sustained current overload exists.
Overcurrent due to low dc bus voltage.
Sustained current overload due to low
dc bus voltage.
IGBT protection circuit detected
overload.
Zero input voltage detected.
Auxiliary inverter DC link energized
while traction inverter DC link
de-energized.
A PSC communication error has
occurred.
A PSC communication error has
occurred.
A PSC communication error has
occurred.
A PSC communication error has
occurred.
A PSC communication error has
occurred.
A PSC communication error has
occurred.
A PSC communication error has
occurred.
A PSC communication error has
occurred.
TCI CPU reset without request.
A data snapshot has been manually
initiated.
Internal software fault.
Limp
Lockout
Possible
Limit
N/A
N/A
10
E2-29

Advertisement